background image

4. This limited warranty applies only to the original purchaser, and then 
only to certified divers. 

5. Sometimes products from other manufacturers are attached to 
Zeagle Equipment.  This warranty does not cover those other products 
or make any claims as to the performance or suitability of those other 
products.

6. This limited warranty applies only to regulators sold in the USA 
through authorized Zeagle Systems dealers.

7. This warranty gives you specific legal rights. You may also have 
other rights that may vary from state to state.

8. This specific warranty applies only to regulators purchased from 
Authorized Zeagle Dealers located within the United States.  Warranty 

coverage in countries other than the US varies.  Outside the US 
your dealer will be able to get further Warranty information from the 
Authorized Zeagle Regional Distributor.

Disclaimer And Limitation On Remedy

(Some states do not allow limitations on how long an implied warranty 
lasts or do not allow exclusion of incidental or consequential damages, 
so the following limitations or exclusions may not apply to you.)
Zeagle expressly limits any and all warranties, expressed or implied, to 
the terms of the limited warranty as set forth above. Your remedies are 
limited to those contained herein and are in lieu of all other remedies, 
whether based on breach of warranty or contract, negligence, strict 
product liability or other tort. Zeagle specifically disclaims liability for 
any consequential, special or indirect damages arising out of the use 
of Zeagle Equipment.

4

Содержание ReZort 310-5210

Страница 1: ......

Страница 2: ...minently hazardous situation which if not avoided will result in death or serious injury This signal word is to be limited to the most extreme situ ations WARNING Indicates a potentially hazardous sit...

Страница 3: ...and Limitation of Remedy Nitrox Use ReZort First Stage Features Second Stage Features Pre Dive Lever Octopus Use Wet Breathing Pre Dive Check Post Dive Care Maintenance Specifications Service Record...

Страница 4: ...been providing divers with Scuba equipment and Buoyancy Control Devices Zeagle Systems and our worldwide network of authorized dealers are always ready to serve you For more information on our product...

Страница 5: ...the first and second stages The first stage serial number is stamped on the first stage on the side of the regulator fig 1 The second stage serial number is stamped on the mouthpiece tube fig 2 To rea...

Страница 6: ...ty coverage in countries other than the US varies Outside the US your dealer will be able to get further Warranty information from the Authorized Zeagle Regional Distributor Disclaimer And Limitation...

Страница 7: ...training agency Diving without the necessary training in safe diving procedures or without observing the practices outlined by your training agency for your level of certification is extremely hazardo...

Страница 8: ...e installed in these ports 2 During installation the O ring hose fittings will seal with hand tight pressure but may come loose during use if not tightened carefully with a small wrench Proper torque...

Страница 9: ...content does not exceed 40 The regulator must be kept Oxygen Clean and used only with certified clean air mixtures to maintain this status Once the regulator is used with air not certified to be clean...

Страница 10: ...and easy to service The ReZort first stage reduces the high pres sure air contained in the cylinder to an intermediate pressure of approximately 135 psi 9 2 BAR Zeagle first stages are designed to do...

Страница 11: ...all conditions DIVE PRE DIVE VENTURI LEVER This lever controls the sensitivity of the regula tor The Plus and Minus Positions for the lever are marked on the case beside the lever To avoid unexpected...

Страница 12: ...hing resistance will be somewhat greater the regulator will still deliver ample air on demand if the lever is accidentally left in the Pre Dive position Longer hoses are available from Zeagle for Octo...

Страница 13: ...nversion and using shorter stronger exhalations if inverted will keep the interior of the regulator drier PRE DIVE CHECK 1 Before mounting any regulator onto a tank valve you must first open the valve...

Страница 14: ...ing on the tank air valve check to make sure that all of the hose connections are tight and that the regulator body is aligned properly with no kinks in the hoses 4 Turn the tank valve on slowly check...

Страница 15: ...he Purge cover with the regulator attached to a pressure source sev eral times to blow the rinse water out of the inner mechanism Allow the entire regulator to air dry before storing For reasons of hy...

Страница 16: ...ve Venturi Lever B SECOND STAGE REGULATOR WEIGHT INTERMEDIATE PRESSURE LOW PRESSURE PORTS HIGH PRESSURE PORTS MATERIALS Body O rings Seat Quick Disconnect Fill Probe 1 4 lb 64 kg 120 150 psi 8 10 bar...

Страница 17: ...15 Service Record Date Service Date Purchased...

Страница 18: ...16 Notes The date of purchase dive store and contact information for the store should be written on this page A copy of the receipt could also be stapled to this page for future records...

Страница 19: ...Zeagle Systems Inc 37150 Chancey Road Zephyrhills FL 33541 Phone 813 782 5568 Fax 813 782 5569 www zeagle com 08 07 p n 175 1646 Revision C 2007 Zeagle Systems Inc...

Отзывы: