10

OCTOPUS (Alternate Second Stage) USE

The diver controls available on Zeagle second stages make them an excel-

lent choice for Octopus use.  An Octopus Regulator is often subjected to 

conditions that may cause a free-flow. To minimize this turn the Resistance 

Control Knob most of the way in (Clockwise) and move the Dive / Pre-Dive 

Lever forward to the “-” Minus position.  When the Octopus Regulator is 

needed for delivering air to a diver, the Resistance Control Knob is turned 

Counter Clockwise to the easiest breathing position, and the Dive / Pre-

Dive Lever is moved back to the DIVE “+” position.  Although breathing 

resistance will be somewhat greater, the regulator will still deliver ample 

air on demand if the controls are accidentally left in the Pre-Dive position.  

Longer hoses are available from Zeagle for Octopus use.

PRE-DIVE CHECK

1. Before mounting any Scuba regulator onto a tank valve, you must open 

the valve briefly to blow out any water trapped in the outlet area of the 

valve.    Failing  to  perform  this  simple  step  will  often  result  in  water  and 

contaminants being blown into the interior of the regulator, which in turn 

will cause future mechanical problems in the regulator.

2. Prior to each dive always check to make certain your regulator has no 

potential water leaks by inhaling lightly on the regulator with the dust cap 

properly installed, or the tank air valve turned off.  You should be able to 

draw in very little if any air.  If you can draw in any quantity of air, either 

the exhaust valve is failing to seal properly, or there may be a pinhole leak 

in the mouthpiece or second stage diaphragm.

3. Mount the 1st stage regulator on the tank valve with the clear diaphragm 

end (with the black logo showing underneath) facing down.

Содержание Flathead VI

Страница 1: ...Flathead VI Owner s Manual...

Страница 2: ...mited to the most extreme situ ations WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situati...

Страница 3: ...ing Nitrox Use First Stages Dry Environmental Sealing Second Stage Features Resistance Control Knob Dive Pre Dive Venturi Lever Octopus Use Pre Dive Check Post Dive Care Maintenance Code Of The Respon...

Страница 4: ...to the second stage with less pressure drop and tremendous capacity Since 1979 Zeagle Systems Inc has been providing divers with Scuba equipment and Buoyancy Control Devices Zeagle Systems and our wor...

Страница 5: ...r regulator at www zeagle com on the internet in the Product Support section The first stage serial number is stamped on the top flat portion of the regulator fig 1 The second stage serial number is s...

Страница 6: ...om state to state Disclaimer And Limitation On Remedy Some States do not allow limitations on how long an implied warranty lasts or do not allow exclusion of incidental or consequential damages so the...

Страница 7: ...Scuba training agency Diving without the necessary training in safe diving procedures or without observing the practices outlined by your training agency for your level of certification is extremely h...

Страница 8: ...ING Cold water is defined as water at a temperature of 50 degrees F 10 C or lower However in cold water there is a risk of the first or sec ond stage freezing The risk of freezing is increased as the...

Страница 9: ...der to a constant intermediate pressure of approximately 135 p s i 9 2 BAR Zeagle first stages are designed to do this with outstanding reliability Extreme cold water diving such as diving under ice r...

Страница 10: ...tal sealing system does not require packing with messy silicone oil or grease This sys tems helps keep the main spring ambient pressure sensing chamber clean and dry and works extremely well in cold w...

Страница 11: ...face or when jumping into the water the lever should be set in the PRE DIVE forward position As soon as the diver is ready to descend the lever should be moved to the DIVE back position NOTE Ask your...

Страница 12: ...hoses are available from Zeagle for Octopus use PRE DIVE CHECK 1 Before mounting any Scuba regulator onto a tank valve you must open the valve briefly to blow out any water trapped in the outlet area...

Страница 13: ...water out of the regulator inlet when changing the tanks Neglect of these simple procedures is a major cause of corrosion and wear in scuba regulators Zeagle s Dry Environmental Sealing System keeps...

Страница 14: ...clean dry regulator in a clean bag or storage box away from sunlight excessive heat and humidity 4 The Valve Seal in the second stage will give longer service if the Resistance Control Knob on the se...

Страница 15: ...are mine with those who have less Superior divers use their superior knowledge to stay out of situa tions that would require their superior skills Your equipment can be excellent but it is not respons...

Страница 16: ...d Resistance Control Knob B SECOND STAGE REGULATOR WEIGHT INTERMEDIATE PRESSURE LOW PRESSURE PORTS HIGH PRESSURE PORTS MATERIALS Body O rings Seat HP Valve 2 18 lb 99 kg 120 150 psi 8 27 10 bar 4 3 8...

Страница 17: ...15 Service Record Date Service Date Purchased...

Страница 18: ...16 Notes The date of purchase dive store and contact information at the store should be written on this page A copy of the receipt could also be stapled to this page for future records...

Страница 19: ...FL 33541 Phone 813 782 5568 Fax 813 782 5569 www zeagle com European Certi cation Information EC Type examination Article 10 by SGS United Kingdom Ltd Weston super Mare BS22 6WA UK Noti ed Body Numbe...

Страница 20: ......

Отзывы: