zBOOST
®
SOHO YX560P USER GUIDE
4
zBOOST
®
SOHO YX560P USER GUIDE
5
IMPORTANT: Before Installing, Please Note These Important Factors in
Determining Performance
•
At least 15 vertical feet is needed between the Signal Antenna (receives the outside signal)
and the Base Unit Antenna (rebroadcasts the signal indoors). Separation less than 15 vertical
feet will result in decreased performance. See illustration below.
•
Keep the Signal Antenna at least 3 feet above any metal.
Determine the Needed Coverage Area
Identify the location in your home/office where you need signal coverage the most. The zBoost
SOHO YX560P can cover up to 3500 square feet (coverage varies based on outdoor signal level,
building construction, and placement of antennas). Walls, ceilings or floors will reduce the coverage
area.
Additional Cable Requirements
If the distance between the Signal Antenna and the Base Unit exceeds 50 feet, extension cables
are available on our website or at many home improvement and electronic stores. The included
cable is RG-6.
The total cable length should not exceed 65 feet unless upgraded cable and/or upgraded Signal
Antenna (see page iv) is used. A longer cable is helpful only if it allows you to place the Signal
Antenna in a location where you measure stronger signal.
Grounding the Signal Antenna
If the Signal Antenna is placed outdoors, it should be properly grounded. (See page iv for a
recommended grounding kit).
The setup must be in accordance with Article 810 of the National Electric Code (NEC). A listed
antenna discharge unit must be provided for the lead-in coaxial cable per NEC article 8.10.20 or the
shield of the coaxial cable must be permanently and effectively grounded in accordance with NEC
article 8.10.21. Please consult a professional installer or electrician for more information.
Securing Cable with a Drip Loop
If the Signal Antenna is placed outdoors, create a drip loop with
the coaxial cable at the point where the cable enters the building
through an outside wall. This can be done by twisting and
securing the cable into a loop (no less than 4” across) near the
entry point. This will help prevent moisture from gathering at entry
point and leaking into the building. Consult a professional installer
for more information.
Power Requirements
The Base Unit can be plugged into a standard 2 or 3 prong 110 VAC receptacle using the included
power supply. The power supply consumes less than 10W (less than 0.2A). For more information
on power consumption, see “Technical Specifications” on page 11.
Warning
The zBoost YX560P base unit MUST only be used with the
provided power adaptor. Use of other power adaptors will
void the warranty and may damage the unit. Use of other
equipment is not FCC approved.
Coax Cable
Exterior Wall
Note
Avoid placing the Signal Antenna near metal such as
wiring, A/C ducts, metal siding, truss plates, etc.
When connecting the cable to the antenna, run the
cable straight down from the antenna. Avoid draping
the coax near the antenna.
15’ of vertical
separation
15’ of vertical
separation
15’ of vertical
separation