 Search ahead for the first non “xx” character from the current cursor position, leaving cursor pointing to non “xx” character. 

Syntax = E6xx 

(xx stands 

for the hex value for an ASCII code.  

E7

 Search back for the first non “xx” character from the current cursor position, leaving cursor pointing to non “xx” character. 

Syntax = E7xx 

(xx stands for 

the hex value for an ASCII code,  

 

Miscellaneous Commands 

FB

 Suppress all occurrences of up to 15 different characters, starting at the current cursor position, as the cursor is advanced by other commands. When the 

FC command is encountered, the suppress function is terminated. The cursor is not moved by the FB command. 

Syntax = FBnnxxyy . .zz 

where nn is a 

count of the number of suppressed characters in the list and xxyy .. zz is the list of characters to be suppressed. (xx stands for the hex value for 

an ASCII code,   

FC

 Disables suppress filter and clear all suppressed characters. 

Syntax = FC

.  

E4

 Replaces up to 15 characters in the data string with user specified characters. Replacement continues until the E5 command is encountered. 

Syntax

 

E4nnxx1xx2yy1yy2...zz1zz2 

where nn is the total count of both characters to be replaced plus replacement characters; xx1 defines characters to be replaced 

and xx2 defines replacement characters, continuing through zz1 and zz2.  

E5

 Terminates character replacement .

Syntax = E5

.  

FE

 Compare character in current cursor position to the character “xx.” , If characters are equal, increment cursor. If characters are not equal, no format 

match. 

Syntax = FExx 

(xx stands for the hex value for an ASCII code.  

EC Check to make sure there is an ASCII number at the current cursor position. If character is not numeric, format is aborted.  

Syntax = EC

.  

ED

 Check to make sure there is a non-numeric ASCII character at the current cursor position. If character is numeric, format is aborted. 

Syntax = ED

 

Data Formatter 

When Data Formatter is turned off, the bar code data is output to the host as read (including prefixes and suffixes). Choose one of the following options. 

Default = Data Formatter On, but Not Required. 

 

 

*Data Formatter On, but Not  
        Required

 

 

 

Data Formatter Off

 

 

When Data Formatter is required, all input data must conform to an edited format or the imager does not transmit the input data to the host device. 

 

               

 

            

Data Formatter On, Format Required

 

 
 
 

Alternate Data Formats 

Alternate formats allow you “single shot” capability to scan one bar code using a different data format than your primary format. When data formats are 

programmed,  you must input whether you are programming the primary format, or an alternate format numbered 1, 2, or 3. An alternate format is initiated 

by scanning one of the 3 alternate format bar codes below. The imager will scan the next bar code, formatting the data with the selected alternate format, 

then revert immediately to the primary format. 

 

 

Alternate Data Format 1

 

 
 

 

 

 

Alternate Data Format 2

 

 

Alternate Data Format 3

 

 

Содержание ZB-3062

Страница 1: ...ZBA Inc 1 ZBA Inc 94 Old Camplain Road Hillsborough NJ 08844 www zbausa com...

Страница 2: ...vel 232 Interface 17 6 1 3 USB HID 17 6 1 4 USB Virtual COM 17 6 2 Pin Assignments 18 7 SYSTEM CONTROL 19 7 1 Scan 19 7 2 Scan 20 7 3 Indication 21 7 4 Thermal and Centering 26 7 5 Decode Search Mode...

Страница 3: ...DF417 54 8 27 EAN UCC Composite Codes 55 8 28 Postal Codes 57 8 28 1 Postnet 57 8 28 2 Planet Code 57 8 28 3 Postal Codes 58 8 28 4 China Post 58 8 28 5 Korea Post 59 8 29 QR Code 59 8 30 Data Matrix...

Страница 4: ...ZBA Inc 4 10 TEST CHART 81 11 INTERFACE ID 84 12 PRODUCT CODE ID 85 13 ASCII CODE TABLE 87 14 OCR PROG CHART 88 15 PROGRAM CHART 89...

Страница 5: ...in any application where failure could result in injury or death If a customer wishes to use ZBA products in applications not intended by ZBA said customer must contact an authorized ZBA representativ...

Страница 6: ...2009 Initial Draft To make a request for change correction additions or information on references please contact ZBA Inc 94 Old Camplain Road Hillsborough NJ 08844 Phone 908 359 2070 Fax 908 595 0909...

Страница 7: ...ired settings have been configured all settings are stored in non volatile memory of scanner after reading configuration barcode labels Recommended steps are as follows 1 Set right host interface for...

Страница 8: ...er has been fully connected turn the terminal computer power back on 3 1 2 USB HID 1 Connect the USB cable between scanner and PC 2 Windows will automatically detect the USB device 3 1 3 USB Virtual C...

Страница 9: ...V V c UPC E0 V V V E UPC E1 E EAN 13 V V V d EAN 8 V V V D Code 39 V b Interleaved 2 of 5 V e Industrial 2 of 5 e IATA 2 of 5 f Matrix 2 of 5 m Codabar V a Code 128 V j Code 93 V i Code 11 V 2 digits...

Страница 10: ...hes sec Depth of Scan Field PCS 90 10 mils 1D 37 175 mm CODE 39 2D 62 137 mm QR code Resolution min 1D 0 127 mm 5 mils 2D 0 21 mm 8 mils Print Contrast 30 or more Focal Point 114 mm 4 5 inches from le...

Страница 11: ...MI CB Environmental Operating Temperature 0 to 50 32 to 122 Storage Temperature 20 to 60 4 to 140 Humidity Up to 95 relative humidity non condensing 50 Light Level Dark to 100 000 Lux Shock 24 drops f...

Страница 12: ...option Transmitted character delay Header selection trailer selection message suffix good read beep tone and volume scanner trigger selection Keyboard emulation type intermessage delay keyboard type...

Страница 13: ...distance from the target send a trigger command and center the aiming beam on the symbol If the code being scanned is highly reflective e g laminated it may be necessary to tilt the code 5 to prevent...

Страница 14: ...igure the proper interface by following interface selection Interface selection You can change factory interface default USB Virtual COM for other type interface By plugging different cables setting r...

Страница 15: ...xt digits and punctuation select 7 data bits For applications which require use of the full ASCII set select 8 data bits per character Default 8 Stop Bits sets the stop bits at 1 or 2 Default 1 Parity...

Страница 16: ...aits for an ACK acknowledge or not acknowledge from the host computer after data transmission and will resend in response to a NAK Response Delay The unit stays awake to receive data until the RS 232...

Страница 17: ...rride allows direct communication from the ZB 3062 to a standard PC RS 232 serial port with the use of cable This setting also allows you to override the polarity externally Default TTL Level 232 Inve...

Страница 18: ...Scanner Side Pin RS 232 USB 1 NC NC 2 VCC VCC 3 TXD TXD 4 NC NC 5 NC NC 6 CTS D 7 RXD D 8 RTS RTS 9 GND GND 10 GND GND Connector to Host Side Pin Definition USB 1 NC 2 TXD D 3 RXD D 4 NC 5 GND 6 NC 7...

Страница 19: ...bar code set the time out duration from 0 300 000 milliseconds by scanning digits from the inside back cover then scanning Save Default 0 infinite or no time out Manual Trigger Low Power For RS 232 on...

Страница 20: ...Presentation Sensitivity is a numeric range that increases or decreases the imager s reaction time to bar code presentation To set the sensitivity scan the Sensitivity bar code then scan the degree o...

Страница 21: ...still audible Volume The beeper volume codes modify the volume of the beep the imager emits on a good read Pitch The beeper pitch codes modify the pitch of the beep the imager emits on a good read Dur...

Страница 22: ...ponse to a good read The beeps and LED flashes are in sync with one another To change the number of beeps scan the bar code below and then scan a digit 1 9 bar code and the Save bar code Beep Polarity...

Страница 23: ...fective in minimizing accidental rereads at POS point of sale Use shorter delays in applications where repetitive bar code scanning is required Reread Delay only works when in Presentation Mode User S...

Страница 24: ...aimer delay allows a delay time for the operator to aim the imager before the picture is taken Use these codes to set the time between when the trigger is activated and when the picture is taken Durin...

Страница 25: ...n dark operating environments Concurrent mode provides the brightest appearance of the illumination LEDs of any of the imager operating modes This mode may be useful for applications when an operator...

Страница 26: ...r this also reduces the intensity of the illumination Reducing the intensity of the illumination reduces total power used but can also reduce the depth of field in low light environments Centering Use...

Страница 27: ...p Bottom Left or Right bar codes Scan Centering On then scan one of the following bar codes to change the top bottom left or right of the centering window Then scan the percent you want to shift the c...

Страница 28: ...center region of an image This mode quickly reads all symbologies in any orientation The Quick Omnidirectional mode may miss some off center symbols as well as larger Data Matrix and QR Code Advanced...

Страница 29: ...ind the symbology to which you want to apply the output sequence format Locate the Hex value for that symbology and scan the 2 digit hex value from the Programming Chart inside back cover 3 Length Spe...

Страница 30: ...h C FF termination string for third code To program the previous example using specific lengths you would have to count any programmed prefixes suffixes or formatted characters as part of the length S...

Страница 31: ...re Output Sequence Required On Not Required Off Multiple Symbols When this programming selection is turned On it allows you to read multiple symbols when the trigger is activated If you press and hold...

Страница 32: ...ideo Reverse Video Reverse is used to allow the imager to read bar codes that are inverted The Off bar code below is an example of this type of bar code If additional menuing is required Video Reverse...

Страница 33: ...ng length the imager will issue an error beep You may set the same value for minimum and maximum length to force the imager to read fixed length bar code data This helps reduce the chances of a misrea...

Страница 34: ...r bar codes printed with a check character but will not transmit the check character with the scanned data Default All Codabar Settings On Off Start Stop Character Transmit Don t Transmit Check Charac...

Страница 35: ...ssage Length Scan the bar codes below to change the message length Minimum and Maximum lengths 2 60 Minimum Default 4 Maximum Default 60 Message Length On Require Maximum Message Length Off Minimum Me...

Страница 36: ...acter at the end of the scanned data Default No Check Character Default All Code 39 Settings On Transmit No Check Character Validate and Transmit Off Don t Transmit Validate but Don t Transmit Message...

Страница 37: ...n and period respectively Character pairs P through Y decode as 0 through 9 Code Page Code pages define the mapping of character codes to characters If the data received does not display with the prop...

Страница 38: ...Transmit the unit only reads Interleaved 2 of 5 bar codes printed with a check digit but will not transmit the check digit with the scanned data When Check Digit is set to Validate and Transmit the im...

Страница 39: ...ting If this is the case scan the bar code below select the code page with which the bar codes were created and scan the value and the Save bar code from the Programming Chart on the inside the back c...

Страница 40: ...aximum Default 48 Default All Straight 2 of 5 IATA Settings On Maximum Message Length Off Minimum Message Length 8 8 Matrix 2 of 5 Message Length Scan the bar codes below to change the message length...

Страница 41: ...with Code 11 bar codes Default Two Check Digits Message Length Scan the bar codes below to change the message length Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 Default All...

Страница 42: ...ngth Scan the bar codes below to change the message length Minimum and Maximum lengths 0 80 Minimum Default 0 Maximum Default 80 Code Page Code pages define the mapping of character codes to character...

Страница 43: ...mager reads symbols with start stop pattern 1 and decodes them as compressed numeric with optional full ASCII start stop pattern 2 Default AIM Telepen Output Message Length Scan the bar codes below to...

Страница 44: ...stem On Off Addenda This selection adds 2 or 5 digits to the end of all scanned UPC A data Default Off for both 2 Digit and 5 Digit Addenda Addenda Required When Required is scanned the imager will on...

Страница 45: ...that lead with the 1 number system Default On UPC E0 Expand UPC E Expand expands the UPC E code to the 12 digit UPC A format Default Off Addenda Required When Addenda Required is set to on the imager...

Страница 46: ...E0 Off UPC E0 Expand On Off Addenda Required Required Not Required Addenda Separator On Off Check Digit On Off Number System On Off Addenda This selection adds 2 or 5 digits to the end of all scanned...

Страница 47: ...3 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not ISBN Translate This selection causes EAN 13 Bookland symbols to b...

Страница 48: ...ger will only read EAN JAN 13 bar codes that have addenda Addenda Separator When this feature is on there is a space between the data from the bar code and the data from the addenda When turned off th...

Страница 49: ...enda Default All EAN JAN 8 Settings On Off Check Digit On Off Addenda 2 Digit Addenda On 5 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda Off Addenda Required When Addenda required is set to on...

Страница 50: ...nly read MSI bar codes printed with the specified type check character but will not transmit the check character with the scanned data Message Length Scan the bar codes below to change the message len...

Страница 51: ...Limited Default All GS1 DataBar Limited Settings On Off 8 20GS1 DataBar Expanded Message Length Scan the bar codes below to change the message length Minimum and Maximum lengths 4 74 Minimum Default 4...

Страница 52: ...st be off Trioptic Code is used for labeling magnetic storage media Default All PosiCode Settings On A and B On No Limited A and B and Limited B On Limited A Off Off A and B and Limited On Limited B O...

Страница 53: ...lt 1 Maximum Default 160 Default All Code 16K Settings On Minimum Message Length Off Maximum Message Length 8 24Code 49 Message Length Scan the bar codes below to change the message length Minimum and...

Страница 54: ...aximum Default 2750 Default All PDF417 Settings On Minimum Message Length Off Maximum Message Length 8 26MicroPDF417 Message Length Scan the bar codes below to change the message length Minimum and Ma...

Страница 55: ...ITF 14 UCC EAN 128 and EAN UCC GS1 DataBar and Composites Data from 2D symbols such as Aztec Code Data Matrix or QR Code which encode a leading FNC1 also invoke EAN UCC emulation If UCC EAN 128 Emulat...

Страница 56: ...ZBA Inc 56...

Страница 57: ...8 28 1 Postnet Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data On Transmit Check Digit Off Don t Transmit Check Digit 8 28...

Страница 58: ...scanned sideways or upside down On Off Australian Post On Off Japanese Post On Off 8 28 4 China Post Message Length Scan the bar codes below to change the message length Minimum and Maximum lengths 2...

Страница 59: ...lt All Korea Post Settings On Minimum Message Length Off Maximum Message Length 8 29QR Code This selection applies to both QR Code and Micro QR Code Message Length Scan the bar codes below to change t...

Страница 60: ...1 Maximum Default 1500 Default All Data Matrix Settings On Minimum Message Length Off Maximum Message Length 8 31MaxiCode Message Length Scan the bar codes below to change the message length Minimum...

Страница 61: ...50 Minimum Default 1 Maximum Default 3750 Default All Aztec Code Settings On Minimum Message Length Off Maximum Message Length Aztec Runes Select Enable Runes if you are scanning Aztec runes which are...

Страница 62: ...utput When Setting up for specific symbologies instead of All Symbologies the symbology ID value counts as an added prefix or suffix character Prefix Scanned Data Suffix To Add a Prefix or Suffix Step...

Страница 63: ...ams a carriage return suffix for all symbologies Prefix Selections Add Prefix Clear One Prefix Clear All Prefix Suffix Selections Add Suffix Clear One Suffix Add CR Suffix All Symbologies Clear All Su...

Страница 64: ...th Character Trigger Delay To remove this delay scan the Delay Length bar code and set the number of steps to 0 Scan the SAVE bar code Interfunction Delay An interfunction delay of up to 495 milliseco...

Страница 65: ...ata Format Step 1 Scan the Enter Data Format symbol Step 2 Primary Alternate Format Determine if this will be your primary data format or one of 3 alternate formats Alternate formats allow you single...

Страница 66: ...followed by xx key or function code Syntax F3ssxx ss and xx both stand for the hex values for ASCII codes F4 Send xx character nn times Insert leaving cursor in current cursor position Syntax F4xxnn...

Страница 67: ...ntax E5 FE Compare character in current cursor position to the character xx If characters are equal increment cursor If characters are not equal no format match Syntax FExx xx stands for the hex value...

Страница 68: ...aracter options are essential for OCR reading 9 5 OCR Fonts Default All OCR Settings turns off all OCR capability in the imager so the imager will be able to scan linear stacked matrix and composite b...

Страница 69: ...tting allows you to scan any eight digit combination If you have created an OCR template character combinations that fit the template can be scanned MICR E 13B On Note TOAD characters Transit On Us Am...

Страница 70: ...haracter To Add an OCR Template 1 Turn on the OCR font you want to read 2 Begin building the template Scan the Enter OCR Template symbol 3 Scan the characters for the string Use the Template Character...

Страница 71: ...ing of three digits For example Note If using Quick View to program use the space bar to designate a space and not the hex value of 20 4 Exit OCR Template Editor Scan Save OCR Template to save your en...

Страница 72: ...ddggg This template would then let you read data that began with six digits and had an A B or C trailing So you would be able to read Reading Multi Row OCR The ZB 3062 is capable of decoding multi row...

Страница 73: ...y combination of seven digits with a modulo 10 check character in the eighth position The template would be dddddddc To create this template you would enable the OCR A font Scan the Modulo 10 Check Ch...

Страница 74: ...h character look up the corresponding hex value from the ASCII Chart 3 Scan the Save bar code on the inside back cover Example To program the modulo 11 check character from example 8 enable the OCR A...

Страница 75: ...to be valid so the reader outputs the message 012845 OCR ISBN Application Example One application of OCR is to read the ISBN characters typically encoded using the OCR A or OCR B font This is especia...

Страница 76: ...emplate Discard OCR Template 9 7 Utilities To Add a Test Code I D Prefix to All Symbologies This selection allows you to turn on transmission of a Code I D before the decoded symbology This action fir...

Страница 77: ...D Prefix to All Symbologies Add Code I D Prefix to All Symbologies Temporary Show Software Revision Show Data Format Show Revision Data Format Settings Standard Product Default Settings Standard Produ...

Страница 78: ...ce s non volatile menu configuration table Use the non volatile table only for semi permanent changes you want saved through a power cycle Query Commands Several special characters can be used to quer...

Страница 79: ...nter cbr Response CBRENA1 ACK SSX0 ACK CK20 ACK CCT1 ACK MIN2 ACK MAX60 ACK DFT ACK This response indicates that the device s Codabar Coding Enable CBRENA is set to 1 or on the Start Stop Character SS...

Страница 80: ...ZBA Inc 80...

Страница 81: ...ZBA Inc 81 10 Test Chart Bar code samples marked with symbol are not enabled initially CODABAR CODE 11 CODE 128 CODE 39 CODE 93 EAN 13 PDF 417 STANDARD 25 CODE 16K EAN 8 87549...

Страница 82: ...ZBA Inc 82 INDUSTRIAL 25 UPC E INTERLEAVED 25 MATRIX 25 MSI PLESSEY UPCA UK PLESSEY PARA GS1 DataBar Micro PDF...

Страница 83: ...ZBA Inc 83 QR Code DataMatrix Aztec MaxiCode...

Страница 84: ...ample a USB Virtual COM device has a Interface ID of 130 You would scan the Interface ID bar code then 1 3 1 then Save If you make an error while scanning the digits before scanning Save scan the Disc...

Страница 85: ...E4 D 0x44 EAN UCC Composite em y 0x79 EAN 13 w Extended Coupon Code E3 d 0x64 Interleaved 2 of 5 Lm e 0x65 Japanese Post X0 J 0x4A KIX Post X0 K 0x4B Korea Post X0 0x3F Matrix 2 of 5 X0 m 0x6D MaxiCo...

Страница 86: ...ZBA Inc 86 Telepen Bm t 0x74 Trioptic Code X0 0x3D UCC EAN 128 C1 I 0x49 UPC A E0 c 0x63 UPC A w Extended Coupon Code E3 c 0x63 UPC E E0 E 0x45 VeriCode X0 v 0x76...

Страница 87: ...ZBA Inc 87 13 ASCII Code Table...

Страница 88: ...ZBA Inc 88 14 OCR Prog Chart...

Страница 89: ...ZBA Inc 89 15 Program Chart...

Отзывы: