ZBA Inc.
62
9 String
Format
9.1 Prefix/Suffix
When a bar code is scanned, additional information is sent to the host computer along with the bar code data. This group of bar code data and additional,
user-defined data is called a “message string.” The selections in this section are used to build the user-defined data into the message string. Prefix and Suffix
characters are data characters that can be sent before and after scanned data. You can specify if they should be sent with all symbologies, or only with
specific symbologies. The following illustration shows the breakdown of a message string:
Prefix / Suffix characters setting
: Characters defined as prefix or suffix characters will be transmitted immediately with the scanned data for all
symbologies. Up to 11 ASCII characters can be defined for both Prefix and Suffix.
Tips
• A prefix or suffix may be added or cleared from one symbology or all symbologies.
• You can add any prefix or suffix f, plus Code I.D. and
AIM
I.D.
• You can string together several entries for several symbologies at one time.
• Enter prefixes and suffixes in the order in which you want them to appear on the output.
• When Setting up for specific symbologies, instead of All Symbologies, the symbology ID value counts as an added prefix or suffix character.
Prefix
Scanned Data Suffix
To Add a Prefix or Suffix:
Step 1.
Scan the
Add Prefix
or
Add Suffix
symbol
Step 2.
Determine the 2 digit Hex value from the Symbology Chart or the symbology to which you want to apply the prefix or suffix. For example, for Code
128, Code ID is “j” and Hex ID is “6A”.
Step 3.
Scan the 2 hex digits or scan
9
,
9
for all symbologies.
Step 4.
Determine the hex value from the for the prefix or suffix you wish to enter.
Step 5.
Scan the 2 digit hex value.
Step 6.
Repeat Steps 4 and 5 for every prefix or suffix character.
Step 7.
To add the Code I.D., scan
5
,
C
,
8
,
0
.
To add AIM I.D., scan
5
,
C
,
8
,
1
.
To add a backslash (\), scan
5
,
C
,
5
,
C
.
Note:
To add a backslash (\) as in Step 7, you must scan 5C twice – once to create the leading backslash and then to create the backslash itself.
Step 8.
Scan
Save
to exit and save, or scan
Discard
to exit without saving. Repeat Steps 1-6 to add a prefix or suffix for another symbology.
Example: Add a Suffix to a specific symbology
To send a CR (carriage return)Suffix for UPC only
:
Step 1.
Scan
Add Suffix
.
Step 2.
Determine the 2 digit hex value for UPC.
Step 3.
Scan
6
,
3
.
Step 4.
Scan
0
,
D
(carriage return).from the
Step 5.
Scan
Save
, or scan
Discard
to exit without saving.
Содержание ZB-3062
Страница 1: ...ZBA Inc 1 ZBA Inc 94 Old Camplain Road Hillsborough NJ 08844 www zbausa com...
Страница 56: ...ZBA Inc 56...
Страница 80: ...ZBA Inc 80...
Страница 82: ...ZBA Inc 82 INDUSTRIAL 25 UPC E INTERLEAVED 25 MATRIX 25 MSI PLESSEY UPCA UK PLESSEY PARA GS1 DataBar Micro PDF...
Страница 83: ...ZBA Inc 83 QR Code DataMatrix Aztec MaxiCode...
Страница 87: ...ZBA Inc 87 13 ASCII Code Table...
Страница 88: ...ZBA Inc 88 14 OCR Prog Chart...
Страница 89: ...ZBA Inc 89 15 Program Chart...