![ZBA ZB-3062 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/zba/zb-3062/zb-3062_user-manual_3206250022.webp)
ZBA Inc.
22
Indicator LED
The LED indicator can be programmed
On
or
Off
in response to a good read.
Polarity
LED Good Read Polarity sets the idle and active states of the LED signal. When set to
Active High
, the LEDs turn on when the signal shifts from low to
high. When set to
Active Low
, the LEDs turn on when the signal shifts from high to low. If the LED is enabled for a good read, the polarity change takes
effect after the next successful decode or a power cycle. If the LED is disabled, a polarity change only takes effect after a power cycle.
Note:
LED Good Read Polarity sets the LED signal voltage level to either high (Active Low) or low (Active High). This will affect LED-Good Read setting.
If the LED has been disabled, make sure it is not turned on accidentally by a polarity change.
LED
*On
Off
Polarity
Active High
*Active Low
Number of Beeps
The number of beeps of a good read can be programmed from 1 - 9. The same number of beeps will be applied to the beeper and LED in response to a good
read. For example, if you program this option to have five beeps, there will be five beeps and five LED flashes in response to a good read. The beeps and
LED flashes are in sync with one another. To change the number of beeps, scan the bar code below and then scan a digit (1-9) bar code and the
Save
bar
code.
Beep Polarity
Beep Polarity sets the idle and active states of the beeper signal. When set to
Active High
, the beeper sounds when the signal shifts from low to high. When
set to
Active Low
, the beeper sounds when the signal shifts from high to low.
If the beeper is enabled for a good read , the polarity change takes effect after the next successful decode or a power
cycle. If the beeper is disabled, a
polarity change only takes effect after a power
cycle.
Note
: Beep Polarity sets the beeper signal voltage level to either high (Active Low) or low (Active High). This will affect Beeper-Good Read settings. If the
beeper has been disabled, make sure it is not turned on accidentally by a polarity change.
Good Read Delay
This sets the minimum amount of time before the imager can read another bar code. Default = No Delay.
User-Specified Good Read Delay
If you want to set your own length for the good read delay, scan the bar code below, then set the delay (from 0-30,000 milliseconds) by scanning digits from
the inside back cover, then scanning
Save
.
Number of Beep
Number of Pulses
Beep Polarity
Active High
*Active Low
Good Read Delay
Содержание ZB-3062
Страница 1: ...ZBA Inc 1 ZBA Inc 94 Old Camplain Road Hillsborough NJ 08844 www zbausa com...
Страница 56: ...ZBA Inc 56...
Страница 80: ...ZBA Inc 80...
Страница 82: ...ZBA Inc 82 INDUSTRIAL 25 UPC E INTERLEAVED 25 MATRIX 25 MSI PLESSEY UPCA UK PLESSEY PARA GS1 DataBar Micro PDF...
Страница 83: ...ZBA Inc 83 QR Code DataMatrix Aztec MaxiCode...
Страница 87: ...ZBA Inc 87 13 ASCII Code Table...
Страница 88: ...ZBA Inc 88 14 OCR Prog Chart...
Страница 89: ...ZBA Inc 89 15 Program Chart...