USER AND MAINTENANCE MANUAL
24
ELECTROPNEUMATIC VALVE
MZD100
4.5.1 Connector
Provide the positioning and the length of the pipes such as to ensure a good accessibility to the valve in
order to easily perform maintenance and cleaning operations.
The connections required for the operation of the MZD100 valve are:
Connect a pipe
Ø
6x4 to the air connection on the
valve.
The air pressure must be between 5÷6 bar.
Connect an electrical two poles cable*, with cross-
section not less than 0.35 mm, to electrical terminals
1 and 2.
Drive air:
Connect a pipe* Ø6x4 to the air
connection on the valve.
The air pressure must be between
5÷6 bar.
Electrical connection:
Connect an electrical
two poles cable* with
cross-section not
less than 0.35 mm
to the solenoid valve
connector.
Fluid supply:
Connect a pipe* to a
fitting G1/8”.
2
1
3
Electrical
terminal 1
Ground
Electrical
terminal 1
4.6
Drive air connection
4.7
Installation diagram
Collegamento
aria
*Parts are supplied separately
*Parts are supplied separately