Zartek CDP-808 Скачать руководство пользователя страница 4

3)

 

The LCD will 

show “ CALLI1G “

 and beep sound will be heard. At the same time, countdown 

of 20 sec (20, 19, 18….) will be seen on the LCD and in case no reply from the handset after 20 
sec, the calling process will stop and the visitor can repeat step 2 to call again. 

   The LCD will show “ NO REPLY PLS TRY AGAIN “ 
 

4)

 

Once the 

handset replies

 by pressing the PTT button, the LCD will show “ CONNECTED “ and 

the visitor can hear voice of the resident. Screen will display “ LISTEN NOW” 

 

5)

 

The 

visitor should speak

 only after he hears the two beeps and when the LCD show 

“CONNECTED otherwise some words will be missed by the resident. Screen will display 
“SPEAK NOW “ 
 

6)

 

The 

handset can reply at any time 

by pressing and holding the PTT button and speaking into 

the microphone, the LCD will show “ CONNECTED “ and the visitor can hear voice of the 
resident. Screen will display “ LISTEN NOW”. Note that the PTT (Push-To-Talk)button should 
be pressed properly in before beginning to speak. 
 

7)

 

Whenever the 

LOCK A

 button K4 on handset is pressed, the door lock will be triggered and 

LCD show “ DOOR A OPENED ”. 
 

8)

 

Whenever the 

LOCK B

 button K5 on handset is pressed, the dry contact will be closed 

momentarily and LCD show “ DOOR B OPENED “. 
 

9)

 

When the 

HA1G UP button

 K2 on handset is pressed, the communication between gate station 

and handset will stop and the unit will return to standby mode. In case the unit cannot receives 
hang up signal from handset (either due to interference from other device or the resident forgets 
to hang up), it will automatically hang up and return to standby mode 60 sec after no signal has 
been received from handset. 
 

10)

 

To 

search for names and house no.

 of residents, press **#. The LCD will show the residents’ 

name and associated house no. in alphabetical order. Press UP/DOWN key to turn page. Once 
you located the name, press the associated house no. and then #. 

 

11)

 

Resident door entry code

       The residents can open the DOOR LOCK A by pressing * followed by the programmed 4 digit 

secret door entry code. The LCD will show “ DOOR ENTRY CODE “ and the gate will open.  

 

12)

 

Infrared detector 

       Whenever the infrared detector detects movement ( 1- 3 m with people approaching towards 

unit or 2- 5m with people walking across unit), the LCD and keypad will be active and light up. 
If there is no further movement it will turn off after 15 seconds.   

 

Back gatestation 
 

It is possible to add an additional gatestation to be used on another or the same entrance, for instance to 
be notified when visitors want to exit. The functions of the back gatestation are similar to the front 
station as all the same names and codes are stored on the station. Gate triggering is limited in that a call 
has to be initiated from the back gatestation in order to be able to trigger the gate it is connected to. A 
system busy function can also be added to the back gatestation with a hard wire connection between 
gatestations. This is used so that the visitor can be notified if the system is busy with another call and 
they must wait. 

 

 

Handset  

Содержание CDP-808

Страница 1: ...luding power supply relay board and external antenna ZA 611 Back side Gate station including power supply relay board and external antenna ZA 612 Programming kits including cable and software ZA 613 H...

Страница 2: ...screen and residents can speak back by pressing the PTT button A gate is opened by pressing the Door lock A or B button and then the call can be ended Handsets can be left on in the charger as there i...

Страница 3: ...tor presses 3 digit code and key on gatestation to call Handset rings and resident answers by pressing PTT Visitor speaks when prompted Resident presses PTT to speak or Lock A or B to trigger gate Res...

Страница 4: ...ignal from handset either due to interference from other device or the resident forgets to hang up it will automatically hang up and return to standby mode 60 sec after no signal has been received fro...

Страница 5: ...ates Each handset is given a unique 3 digit code when it is programmed to the gatestation This code is the handsets number or house s unit number Different coded handsets cannot speak to each other In...

Страница 6: ...tton so the button must remain pressed in whilst you speak directly into the microphone 4 Lock A button K4 During communication with gate station pressing K4 can activate relay A with 1amp rating and...

Страница 7: ...re is more than one handset paired with the same house no this ringing tone time must be set same for all handsets or it will follow the longest time 9 Trigger Lock Disable Function K1 K6 Press K1 whi...

Страница 8: ...The gate open icon X18 will show up momentarily in LCD together with the respective letter A or B once the gate station receives such command successfully 6 Upon finishing communication the resident c...

Отзывы: