![zarges Z200 Скачать руководство пользователя страница 14](http://html2.mh-extra.com/html/zarges/z200/z200_assembly-and-usage-instructions_3215123014.webp)
Operating and assembly instructions
Z200 / Z300
14
2.8. Parts list incl. ballasting (see also 5.2)
The parts list includes the designation of the individual parts, their associated weights, the item
no. of the individual parts which are included in the complete scaffold and the item no. of the
complete scaffold. The necessary ballasting per scaffold is also listed.
Z200 / Z300 mobile scaffold towers
Scaff
old size
W
orking height
1)
P
arts lis
t
Basic fr
ame 1.75 m
Folding unit
Slip-in fr
ame 1 m
Slip-in fr
ame 2 m
Railings
2)
Platf
orm with
fl ap
Cr
os
swise boar
d
Lengthwise boar
d
Diagonal br
ac
e
Horizontal br
ac
e
Chas
sis beams
3)
Stabiliser
s
Base plates
Ballas
ting
Interior
usage
Outdoor
usage
centr
e er
ection
side er
ection
2)
centr
e er
ection
side er
ection
2)
approx. [m]
Order
no.
44400
44468
44407
44405
-
44435
44445
44440
44420
44410
44450
44455
44459
Z200 0.7 × 1.5
2.55
48409
-
1
-
-
1
-
-
-
1
-
-
4
Number of ballas
t w
eights o
ver each swiv
el cas-
tor
0
0
0
0
2.80
48400
2
-
-
-
1
-
-
1
1
-
-
4
0
0
0
0
5.00
48401
-
-
2
1
-
2
2
2
5
2
-
-
3
3/3
3
3/3
7.00
48402
-
-
-
2
1
-
-
3
4
-
-
-
5
7/7
5
7/7
9.00
48403
-
-
-
2
-
-
-
2
-
-
4
-
2
2/2
2
2/2
approx. [m]
Order
no.
44400
44404
44407
44405
44413
44436
44445
44441
44421
44411
44451
44455
44459
44460
4)
Z300 0.7 × 2.0
2.55
44509
-
1
-
-
-
1
-
-
-
1
-
-
4
0
0
0
0
2.80
44500
2
-
-
-
-
1
-
-
1
1
-
-
4
0
0
0
0
5.00
44501
-
-
2
1
2
-
2
2
2
1
2
-
-
1
1/2
1
1/2
7.00
44502
-
-
-
2
2
1
-
-
3
-
-
-
-
3
3/5
4
3/5
9.00
44503
-
-
-
2
-
-
-
-
2
-
-
4
-
0
0/0
2
0/0
12.00 44504
-
-
-
3
2
1
-
-
2
-
-
-
-
2
2/2
2
2/2
1)
With footplates; when swivel castors 44 454 are used = 22 cm to max. 33 cm; 44 453 = +16 cm (at an extra cost). Ballast weights
not included in the scope of delivery.
2)
Is replaced with 2 horizontal braces.
3)
Length of the chassis beams for the Z300: 1.65 m of galvanised steel; for the Z200: 1.50 m of aluminium.
4)
In the case of side erection, sometimes more ballast weights are located on the side facing away from the wall.
(Example: 3/5 = 3 weights on the side facing the wall and 5 ballast weights on the side facing away from the wall)
With more than 4 ballast weights per swivel castor, additional slip-in pipes (44449) must be used.
Pay attention to the ballasting specifi cations in the operating and assembly instructions!
Z200-300-AA-RC4_EN.indd 14
Z200-300-AA-RC4_EN.indd 14
28.02.2008 10:21:01
28.02.2008 10:21:01