- 39 -
STEP 4:
Test Hook-Up Wire
Remove fence controller power source
(unplug or disconnect from battery) and
disconnect hook-up wire from fence line.
Power fence controller and then check
hook-up wire as shown.
STEP 5: Check Fence Components
Walk your fence line and inspect all components. Insulators should be
clean and not cracked. Fence wire should be properly spliced, not
touching fence posts and properly connected at all points. Verify
weeds, branches or other debris are not touching the fence line.
STEP 6:
If you are still getting inadequate voltage readings visit
ZarebaSystems.com for further tips or call Zareba Systems customer
service at 800-800-1819.
100 yards
To fence
controller
(GROUND
terminal)
To fence controller
(FENCE terminal)
Short the fence using
a metal bar or wire
Push probe
into ground
Touch ground rod with tester. If reading is over 400 volts,
grounding is inadequate. Add additional ground rods 6 feet apart
connected by hook-up wire until reading is under 400 volts.
STEP 3:
Test Ground System
Touch tester
contacts to
hook-up wire.
To FENCE
terminal