- 23 -
Fence
Controller
Utility
ground
50 '
Water tank
Water pipeline (or other buried metal)
Ground rods
Ground Installation Around Buried Metal
Ground Installation Around Buried Metal
WARNING:
Do not install ground rods within 50 feet of a utility
ground rod, buried telephone line or buried metal water line, as they
may pick up stray voltage .
Hot fence wire
Hot fence wire
Ground return wire
Additional ground rod every 1,300’
Standard ground system
Fence
controller
Animal makes contact with BOTH hot
and ground wire to recieve shock
Grounding in Dry or Frozen Ground
In dry, sandy or frozen soil a typical grounding system is insufficient
because electricity can not flow back to the fence controller. To
compensate, create a ground wire return system with one fence wire
carrying electricity back to the fence controller’s ground terminal. Run
the ground return wire between hot/electrified wires and drive a
6-foot galvanized steel or copper rod every 1,300 feet. Regardless of
the soil conditions, when the animal contacts the hot and ground
wires simultaneously, they will feel a shock.
Tip
: Because the animal must contact the hot and ground return
wire SIMULTANEOUSLY, we recommend these two wires be spaced
within two to three inches of each other .