AFGZP0BA – SMART CONSOLE - User Manual
4.2 CNX Connector
CNX is the main connector of the Smart Console.
The layout is a female DA-15 connector and it belongs to the D-subminature
family of connectors for computer and communication system.
4
DA-15 connector has been chosen because it is widely available on the market.
Even if Zapi is always available to design custom cables, the customer is
encouraged to create its own cables depending on its need.
U
The connector has two
threaded nuts which accept screws on the male
connector. It is strongly recommended to lock the screws in order to
improve electrical connection quality and to avoid undesired
disconnections
.
4.2.1 Layout
4.2.2 Pin description
PIN SIGNAL
DESCRIPTION
CNX1
GND
This is the ground of the console.
Ground shall always
be connected to the ground of the
controller/application.
CNX2
PRX
Positive of serial reception. It is a signal used in serial
communication only.
CNX3
NRX
Negative of serial reception. It is a signal used in serial
communication only.
CNX4
NTX
Positive of serial transmission. It is a signal used in serial
communication only.
CNX5
PTX
Negative of serial transmission. It is a signal used in serial
communication only.
CNX6
CANL
Signal of CANBUS interface. By default no 120
Ω
resistance is placed between CNX6 and CNX7.
Содержание SMART CONSOLE