49
Fig. 24
FO 0392
Gas
Burner
Injector
Nominal
Nominal
Minimum By-Pass Feeding
Type
1/100
Power
Flow Rate
Power
1/100
pressure
mm
Rate
in
Rate
(mbar)
(kW)
m³/h
g/h
(Kw)
Natural
Auxiliary
70
1,0
0,095
-
0,33
gas
Semi-rapid
96
2,0
0,190
-
0,45
adjustable
20
G20
Rapid
119
3,0
0,286
-
0,65
Liquid
Auxiliary
50
1,0
-
72
0,33
28
gas
Semi-rapid
71
2,0
-
144
0,45
32
30
G30/G31
Rapid
86
2,8
-
202
0,65
40
Injector replacement
• Remove the pan supports.
• Remove the burner's caps and crowns.
• With a socket spanner 7 unscrew and
remove the injectors (Fig. 24), and replace
them with the ones required for the type
of gas in use (see the table below).
• Reassemble the parts, following the same
procedure backwards.
• Replace the rating label (placed near the
gas supply pipe) with the relevant one for
the new type of gas supply. You can find
this label in the package of the injectors
supplied with the appliance.
Should the feeding gas pressure be different
or variable compared with the required
pressure, an appropriate pressure adjuster
must be fitted on the gas supply pipe, in
compliance with the rules in force.
Adaptation to different types of gas