24
1
IMPORTANT!
Risk of injury from electrical current.
Loose and inappropriate plug and socket connections can make the termi-
nal overheat.
•
Have the clamping joints correctly installed by a qualified electrician.
•
Use strain relief clamp on cable.
•
In the event of single-phase or two-phase connection, the appropriate
mains cable of type H05BB-F Tmax 90°C (or higher) must be used.
•
If this appliance’s mains cable is damaged, it must be replaced by a spe-
cial cable (type H05BB-F Tmax 90°C; or higher). Please contact your local
Service Force Center for further advice.
A device must be provided in the electrical installation which allows the ap-
pliance to be disconnected from the mains at all poles with a contact open-
ing width of at least 3 mm
Suitable isolation devices include line protecting cut-outs, fuses (screw type
fuses are to be removed from the holder), earth leakage trips and contac-
tors.
Electrical Connection Diagram
For UK only: 230V...240V~