INSTALLING THE COOKER HOOD

Please ensure that when the appliance is
installed it is easily accessible to an
engineer in the event of a breakdown.

All installations must comply with the local
authorities requirements for the discharge of
exhaust air.

Incorrect installation may affect the safety of
this cooker hood.

Installation Requirements

Before installation check the wall to which the
cooker hood is to be fitted for electric cables,
water pipes or gas.

If it is necessary to fix the hood to a hollow
construction plaster or partition board
structure then it should be sufficiently
reinforced to be quite rigid in the area of the
cooker hood mounting brackets, and the
appropriate rawl plugs used for this type of
fixing (not supplied).

Ducting

The ducting must be fire retardant 100mm (4ins)
in diameter and the length should be no
more than:
3 metres with one 90° bend
2 metres with two 90° bends
Bends of more than 90° will reduce the
efficiency of the hood and reduce the airflow.

Clearance Height

The cooker hood is designed to be fitted over
a cooking appliance at the clearance heights
stated, providing the maximum output of the
appliance beneath does not exceed the
maximums quoted in the Technical Specifications.

If the output of the appliance below the cooker
hood exceeds the maximum outputs quoted,
please refer to the cooker manufacturer’s
installation instructions.

Содержание ZHI 600

Страница 1: ...INTEGRATED COOKER HOOD ZHI 600 INSTRUCTION BOOKLET...

Страница 2: ...our Appliance Operating Instructions Cooker Hood Controls To Operate Extraction mode Recirculation Maintenance and Cleaning External Cleaning Synthetic Paper Grease Filter To Replace the Synthetic Pap...

Страница 3: ...e cut out device will reset itself when the fan motor has cooled significantly It is dangerous to alter the specifications or modify this product in any way When installed between adjoining wall cabin...

Страница 4: ...and leave it running for approximately 15 minutes after finishing Cooker Hood Controls S Automatic Microswitch The microswitch overrides the controls and switches off the hood when the visor is closed...

Страница 5: ...l filter is not required Never do flamb cooking under this cooker hood Take extra care when frying and never leave frying pans unattended during use as over heated fats and oils can catch fire Do not...

Страница 6: ...has saturation indicators which are small squares made from a series of dots When the white paper inside the squares becomes saturated with grease the coloured dots start to run and spread across the...

Страница 7: ...arcoal Filter 1 Remove the thumb screw through the center of the charcoal filter from the motor support 2 The charcoal filter can now be removed This appliance can be a fire hazard if the grease and c...

Страница 8: ...f fresh air If set up for recirculation check that the charcoal filter is still effective If set up for extraction check that the ducting and outlets are not blocked The safety cut out device has been...

Страница 9: ...parts of glass or plastic Costs incurred for calls to put right appliances improperly installed or calls to appliances outside the United Kingdom Appliances found to be in use within a commercial envi...

Страница 10: ...nent electrical installation must comply with the latest I E E Regulations and local Electricity Board regulations For your own safety this should be undertaken by a qualified electrician e g your loc...

Страница 11: ...reinforced to be quite rigid in the area of the cooker hood mounting brackets and the appropriate rawl plugs used for this type of fixing not supplied Ducting The ducting must be fire retardant 100mm...

Страница 12: ...be 450mm If the height of the wall cabinet is less than 450mm a gap of 50mm must be maintained either side of the hob This cooker hood must not be installed above a cooking appliance with a high leve...

Страница 13: ...e by pressing inwardly on the actuator bolts at each side of the grille while pulling the grille panel downwards The grille panel will slide into the intermediate position Raise the lower edge of the...

Страница 14: ...be secured on each side to the adjoining wall cabinets using the 4 x 15mm 1 2 ins security screws provided 5 Adjust the lower spacer panel at the rear of the hood to close the gap to the wall Decor Pa...

Страница 15: ...in the bottom of the casing 3 Push the visor in until an audible click is heard 4 The visor can now be opened and closed in its normal function Adjustment If a heavy door is fitted or if the visor wil...

Страница 16: ...r 3 Clear and concise details of the fault 4 The model and serial number found on the rating plate 5 The purchase date Please note that a valid purchase receipt or guarantee documentation is required...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...436002545 01 041222 Electroluxplc2002...

Отзывы: