www.schweigen.com.au
Revision V2_161219
RANGEHOOD & INSTALLATION GUIDE
EV-6UCQ
EV-9UCQ
Страница 1: ...www schweigen com au Revision V2_161219 RANGEHOOD INSTALLATION GUIDE EV 6UCQ EV 9UCQ ...
Страница 2: ...Contents 6 Operation 6 Cutout Size 6 4 Installation 7 Rangehood Size Vs Cooktop Size 7 Overhead Cabinet Rangehood Installation Position 7 Recommended Installation Height For Induction Cooktop 8 Mounting Points 9 Overview 10 5 Condensation Information 11 6 Troubleshooting 12 7 Service 13 8 Specifications 14 Dimensions 14 Technical Specifications 14 9 Disclaimer 15 ...
Страница 3: ...cal functions of the canopy before installation Canopy is heavy Please ensure adequate care when installing to prevent personal injury A power outlet should be within reach of the power cord exit from the rangehood The canopy hood is not intended for use by persons including children with reduced physical sensory or metal capabilities or lack of experience and knowledge unless they have been given...
Страница 4: ... power before cleaning The rangehood surface should be cleaned with soft cloth and non corrosive detergent Wash with warm soapy water and a soft sponge Never use abrasive detergent scouring pads steel wool or solvents on any part of this appliance Always make sure to dry the appliance after cleaning and never leave wet as this will cause irreparable damage Clean the interior of the rangehood with ...
Страница 5: ...rd For Users This product is designed for household use and should not be used outside or for commercial applications After use always ensure that all controls are in the OFF position When frying with a gas flame take particular care not to allow the oil or grease in the pan to catch fire Flambé Do not leave the frying pan or fryer unattended as the oil could overheat and catch fire Never flambé a...
Страница 6: ... removed before use Note Dimensions may be subject to change Operation This undermount is equipped with an ON OFF switch When the ON position is selected the unit will run at maximum When the OFF position is selected the rangehood will turn off Fan 1 2 3 I is the ON position and O is the OFF position Light 3 I is the ON position and O is the OFF position Cutout Size Please use this as a guide only...
Страница 7: ... and overhead cabinetry depth before installing the rangehood The information below is to be used as a guide only drawings are not to scale and do not account for all circumstances The cooktop is centrally installed in the benchtop in the diagrams below GOOD 600mm 600mm 600mm 400mm Side View Side View BETTER 450mm BEST 500mm When the overhead cabinetry is constructed and installed deeper than stan...
Страница 8: ...m height above the cooking surface Schweigen declines responsibility for damages suffered by the rangehood due to excess heat or damage to objects people and others caused directly or indirectly by a malfunction breakage or fire Recommended Installation Height for Induction Cooktop To help avoid condensation particular to cooking with an induction cooktop Schweigen recommends a height of 700mm Ref...
Страница 9: ... VIEW SIDE VIEW Bottom View Front View Side View Mounting point A and B need to be tighted with slightly angled screws to pull the rangehood up tight to the cabinet These support screws insert from the bottom of the rangehood These support screws insert from the inside of the cabinet A B Wall Cabinet TOP VIEW BOTTOM VIEW SIDE VIEW SIDE VIEW Front TOP VIEW SIDE VIEW SIDE ...
Страница 10: ...ducting secured in place 9 Connect flexi ducting to the outlet on rangehood using duct tape or cable tie Please DO NOT rip the ducting NOTE The motor system does not include a roof seal kit support straps duct tape and cable ties There is a separate Motor Installation Guide in the Motor Box Flexi Ducting IMPORTANT For the motor to operate efficiently do not crush or kink the flexi ducting as it wi...
Страница 11: ...angehood Speed of food liquid heating Angle of ducting Sshweigen S bend preferred Filter size larger canopy preferred Quality of pots or cookware you are using high quality recommended How to reduce the possibility of condensation forming Ensure the rangehood is installed by a qualified professional carefully following the installation guide Turn on the rangehood 5 10 minutes prior to cooking and ...
Страница 12: ... switch should be at on position Check metal filter Metal filter should be washed regularly see filter cleaning Check lamps Lamps should be firm Check outlet Outlet should be open Check lamps Make sure they are not broken or faulty Replace if broken Please make sure there is no obstruction in ducting and back draft fins Check the outlet make sure it is not blocked and you have the correct diameter...
Страница 13: ...ailure is not due to the faults mentioned in Troubleshooting contact the customer service centre In Australia Customer Service 1300 829 066 In New Zealand Customer Service 0800 200 510 Lodging an Online Service Request In the event that failure is not due the reason s in the trouble shooting section you can lodge an online Service Request To lodge Service Request visit our website https www schwei...
Страница 14: ...ifications Technical Specifications Model EV 6UCQ EV 9UCQ Feeding Voltage 220 240V 50Hz Lamp Power 2 x 25W Approval Number DIMENSIONS EV 6UCQ EV 9UCQ 866 900mm 261 295 245 237 267 30 245 600mm 566 295 261 237 267 30 ...
Страница 15: ...eliance upon such information All pictures used in the guide are for illustrative purposes only The symbol on the product or its packaging indicates that it cannot be treated as normal household waste Take this product to your nearest electrical and electronic equipment waste point for recycling By correctly disposing of this product you will be helping to prevent potentially negative consequences...
Страница 16: ...d Court Mulgrave 3170 Victoria Phone 1300 881 693 Email sales schweigen com au Web www schweigen com au New Zealand 5 Tolich Place Henderson Auckland 0610 Phone 0800 200 510 Email info parex emerson com Web www parex co nz ...