background image

17

Rear Left Burner

(semi-rapid)

Heat Input

2.0 kW (6824 BTU/HR)

Front Left Burner

  (auxiliary)

Heat Input

1.0 kW (3412 BTU/HR)

Rear Right Burner

(semi-rapid)

Heat Input

2.0 kW (6824 BTU/HR)

Front Right Burner:

(Ultra-rapid Triple-crown)

Heat Input

4.0 kW (13652 BTU/HR)

Instructions for the Installer

Engineers technical data

Overall dimensions

Width:

580 mm.

Depth:

510 mm.

Cut out dimensions

Width:

560 mm.

Depth:

480 mm.

Supply connections

Gas:

RC 1/2 inch (1/2 inch male) Rear right hand corner

Electric:

220V - 50Hz supply, 3 core flexible cable with non
rewireable plug fitted with a 3 amp cartridge fuse.

Burner

Dia. Tap By-pass

1/100 mm

Auxiliary

28

Semi-rapid

32

Ultra-rapid (triple-crown)

56

Aeration adjustment none

BURNER

ULTRA-RAPID

SEMI-RAPID

AUXILIARY

(triple crown)

(medium)

  (small)

POSITION

MAX

MIN

MAX

MIN

MAX

MIN

 NOMINAL THERMAL
 POWER                  kW

4.0

1.2

2.0

0.45

1.0

0.33

 NOMINAL FLOW
 RATE                     m

3

/h

0.381

0.114

0.190

0.043

0.095

0.031

 NOZZLE REFERENCE

146

Adjust.

96

Adjust.

70

Adjust.

 NOMINAL THERMAL
 POWER                  kW

4.0

1.2

2.0

0.45

1.0

0.33

 NOMINAL FLOW
 RATE                     g/h

288

86

144

32

72

24

 NOZZLE REFERENCE

98

56

71

32

50

28

NATURAL GAS

20 mbar

TYPE OF

GAS

Characteristics

LPG GAS

28-30/37 mbar

1/100 mm

1/100 mm

VALUE = 49.92 MJ/Kg

VALUE = 37.78 MJ/m

3

Ws - 50.7 MJ/ m

3

APPLIANCE CLASS

 : 3

APPLIANCE GAS SUPPLY

: gas G28-30 / 37mbar

Содержание ZGF 68

Страница 1: ......

Страница 2: ...venting hose z When using the hob for a long period of time the ventilation should be improved by opening a window or increasing the extractor speed z Do not use this hob if it is in contact with water Do not operate the hob with wet hands z Ensure the control knobs are in the OFF position when not in use z When using other electrical appliances ensure the cable does not come into contact with the...

Страница 3: ...9 336 Electromagnetical Compatibility Directive 90 396 Gas Appliances and subsequent modifications For the User Contents For the Installer Important Safety Information 12 Description of the Hob 13 Operation 14 Maintenance and Cleaning 15 Something Not Working 16 Service and Spare Parts 16 Instructions for the Installer 17 Installation 19 Conversion from Natural Gas to LPG 19 Commissioning 20 Elect...

Страница 4: ...should only use pots and pans with a flat bottom fitting the size of the burner used see table Operation Burner minimum maximum diameter diameter Ultra rapid Triple crown 180 mm 260 mm Medium semi rapid 120 mm 220 mm Small Auxiliary 80 mm 160 mm If you use a saucepan which is smaller than the recommended size the flame will spread beyond the bottom of the vessel causing the handle to overheat Take...

Страница 5: ...roceed as shown in Fig 3 Take care when removing them They are heavy and could damage the hob or your kitchen furniture if you let them fall Never turn the pan supports on the hinges this could damage them To remove the pan supports completely proceed as shown in Fig 3 Wash the pan supports using hot soapy water If necessary a paste cleaner or a soap impregnated steel wool pad can be used with cau...

Страница 6: ... the main jet is not blocked and the burner crown is clear of food particles Check the burner cap and crown have been replaced correctly e g after cleaning Service and original spare parts This machine before leaving the factory has been tested and studied by many experts and specialists in order to give you the best results Any repair work which needs to be carried out should be done with the utm...

Страница 7: ...ireable plug fitted with a 3 amp cartridge fuse Burner Dia Tap By pass 1 100 mm Auxiliary 28 Semi rapid 32 Ultra rapid triple crown 56 Aerationadjustmentnone BURNER ULTRA RAPID SEMI RAPID AUXILIARY triple crown medium small POSITION MAX MIN MAX MIN MAX MIN NOMINALTHERMAL POWER kW 4 0 1 2 2 0 0 45 1 0 0 33 NOMINALFLOW RATE m3 h 0 381 0 114 0 190 0 043 0 095 0 031 NOZZLEREFERENCE 146 Adjust 96 Adjus...

Страница 8: ...ired while if the volume exceeds 11 m3 no air vent is required However if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3 If there are other fuel burning appliances in the same room B S 5440 Part 2 Current Edition should be consulted to determine the requisite air vent requirements Location The hob may be located in a kit...

Страница 9: ...aded elbow adjustment is fixed so that the washer is fitted between the components as shown in the diagram Screw the parts together without using excessive force FO0264 Conversion from LPG to Natural Gas IMPORTANT The replacement conversion of the gas hob should only be undertaken by a competent person It is important to note that this model is designed for use with LPG gas but can be converted fo...

Страница 10: ...ent screw Electrical connections Neutral Earth yellow green The appliance is designed to be connected to 220 V monophase electricity supply The connection must be carried out in compliance with the laws and regulations in force Before the appliance is connected 1 checkthatthemainfuseandthedomesticinstallation can support the load see the rating label 2 check that the power supply is properly earth...

Страница 11: ...liquids Dimensions are given in mm Building In Building over a cupboard or drawer If the hob is to be installed above a cupboard or drawer it will be necessary to fit a heat resistant board below the base of the hob on the underside of the work surface Building over a kitchen unit with door Proper arrangements must be taken in designing the furniture unit in order to avoid any contact with the bot...

Страница 12: ...22 Rectangular cut out size for hob Cut Out Size The dimensions of the cut out are given in the diagram FO2038 100 Dimensions are given in mm ...

Страница 13: ...23 ...

Страница 14: ...Grafiche MDM Forlì 35692 6501 05 06 www electrolux com ...

Отзывы: