20
Commissioning
When the hob has been fully installed it will be necessary
to check the minimum flame setting. To do this, follow
the procedure below.
-
Turn the gas tap to the MAX position and ignite.
-
Set the gas tap to the MIN flame position then turn
the control knob from MIN to MAX several times. If
the flame is unstable or is extinguished follow the
procedure below.
)
Procedure:
-
Re-ignite the burner and set to MIN.
-
Remove the control knob and use a thin bladed
screwdriver to turn the adjustment screw until the
flame is steady and does not extinguish, when the
knob is turned from MIN to MAX.
-
The adjustment screw may be located at the centre
of the gas tap control shaft or on the gas tap body,
left of the control shaft or below (see diagram).
-
Repeat the adjustment procedure for all burners.
)
Pressure Testing
-
Remove left hand pan support and front left burner
cap and crown.
-
Fit manometer tube over the injector.
-
Turn on the burner gas supply and ignite another
burner.
-
The pressure reading should be nominally 20mbar
and must be between 17 mbar and 25mbar.
-
Turn off the burner supplies.
Adjustment
screw
Electrical connections
Neutral
Earth (yellow/green)
The appliance is designed to be connected to 220 V
monophase electricity supply.
The connection must be carried out in compliance with
the laws and regulations in force.
Before the appliance is connected:
1) check that the main fuse and the domestic installation
can support the load (see the rating label);
2) check that the power supply is properly earthed in
compliance with the current rules;
3) check the socket or the double pole switch used for
the electrical connection can be easily reached with
the appliance built in the forniture unit.
Connect the plug, able to support the load marked on the
identification plate, to the cable. The plug has to be fitted
in a proper socket.
If connecting the appliance directly to the electric system,
it is necessary that you install a double pole switch
between the appliance and the electricity supply, with a
minimum gap of 3 mm. between the switch contacts and
of a type suitable for the required load in compliance with
the current rules.
The earth cable (yellow/green) must not be interrupted by
the interrupter.
The connection cable has to be placed in order that, in
each part, it cannot reach a temperature of 90 °C.
The brown coloured phase cable (fitted in the terminal
block contact marked with "L") must always be connected
to the network phase.