69
Instructions for the installer
The following instructions are meant for a qualified
installer, in order that the operations of installation,
regulation, and service are executed according to the
existing regulations.
Whenever changes are mode involving the disconnection
of the machine it is necessary to proceed with maximum
caution.
THE MANUFACTURING COMPANY DECLINES
ANY RESPONSABILITY FOR POSSIBLE
DAMAGES
RESULTING FROM AN INSTALLATION WHICH
DOESN'T COMPLY WITH THE RULES IN FORCE
Installation environnement
Warning - This unit can be installed and can work only
in constantly ventilated rooms, according to rules in
force.
In order to make the gas unit work properly, it is
necessary that air sufficient to gas combustion can
naturally flow in the room. (The installer must follow the
rules in force).
The air flow into the room must come directly through
openings of external walls. These openings (or opening)
should be realized in such a way not to be occluded both
from inside and outside.
Installation and maintenance must be carried out by a
qualified technician, in compliance with rules in force,
particularly NBND 51003.
The electric coonection must be carried out in
compliance with rule NBN.
Our responsability will not be involved in case of
accidents caused by a defective or non existent
earth connection.
Combustion products discharge
Gas cooking units must discharge combustion products
through hoods directly connected to flues or outside.
Oven:
Grill
1800 W
Oven lamp (not in mod. ZCG 5250)
15 W
Turning spit
4 W
Max. power rating:
- ZCG 5250
1880 W
- ZCG 6220
1815 W
- ZCG 6650
1820 W
Voltage tension (50 Hz)
230 V
Technical data
Dimensions of the appliance
Height
850 mm
Width
ZCG 5250
500 mm
ZCG 6650 - ZCG 6220
600 mm
Depth
600 mm
Appliance Class 1 and Class 2 Sub-Class 1
Category:
II 2E+3+
Appliance set for use with gas type:G20/G25 20/25 mbar
Содержание ZCM6650
Страница 18: ...73 ...
Страница 20: ...75 ...
Страница 21: ...35666 9605 10 00 Grafiche MDM Forlì ...