70
Positioning
This appliance belongs to the class "X". It has been
designed to be placed close to furniture units not
exceeding the height of the working level (EN 60 335-2-6)
Levelling
The appliance is provided with adjustable small feet
placed in the back and front corners od the base.
By adjusting the small feet (fig.12) it is possible to
change the height of the appliance so as to ensure a
better levelling with other surfaces and a uniform
distribution of the liquids contained in pans or pots.
Gas connection
Gas connection must be carried out according to the
rules in force. The manufacturing company release the
unit, once tested, adjusted for the kind of gas stated on
the rating plate located on the back of the range, next to
connection pipe. Be sure that you are going to connect
the unit to the same kind of gas written on the plate.
Connection using a rigid pipe or
a flexible metal pipe
To ensure higher safety, it is recommended to carry out
the connection to the gas system using rigid pipes (ex.
copper) or using flexible stainless steel pipes, to avoid
any stress to the unit. Gas feeding pipe fitting is Gc 1/
2. For this type of installation, connection to the gas
supply should be carried out using only and exclusively
flexible metallic tubes in conformity with rules in force.
Connection using flexible non
metal pipes
When the connection can be easily inspected in its full
extent, there is the chance to use a flexible pipe
according to the rules in force. The flexible pipe must be
tightly fixed using clamps according to the rules in force.
The flexible pipe should be made ready for use in such
a way that:
- nowhere it can reach overtemperature, other than
room temperature, higher than 30°C; if the flexible
pipe, to reach the cock, must run behind the range,
it must be installed as shown in Fig. 14;
- it is no longer than 1500 mm;
- it shows no throttles;
- it is not subject to traction or torsion;
- it doesn't get in touch with cutting edges or corners;
- it can be easily inspected in order to check its
condition.
The control of preservation of the flexible pipe consists
in checking that:
- it doesn't show cracks, cuts, marks of burnings both
on the end parts and on its full extent;
- the material is not hardened, but shows its normal
elasticity;
- the fastening clamps are not rusted;
- expiry term is not due.
If one or more abnormalities are seen, do not repair the
pipe, but replace it.
IMPORTANT
Once installation is complete, check the perfect
seal of every pipe fitting, using a soapy solution,
never a flame.
Fig. 12
FO 0063
Fig. 13
FO 0163
YES
NO
ELECTRIC WIRE
FLEXIBLE RUBBER
GAS PIPELINE
ELECTRIC WIRE
FLEXIBLE RUBBER
GAS PIPELINE
Fig. 14
Fig. 15
FO 0392