29
7.2
Connection to w ater system
(
water condenser
)
This connection is only necessary if the unit has a water-cooled condenser. It is
effected by following the indications of the tags positioned by the inlet and outlet
pipes. Connection pipes should never be smaller in diameter than those on the unit. A
minimum water pressure of 1 bar is required for correct operation of the unit.
8
Electric controls
8.1
Control panel
SET
Press and release
Display and modify the Setpoint
Confirms commands
PRG
Press and release
Displays any alarms (if active)
Opens Machine Status menù
Confirms commands
Press for at least 3 sec
Opens Programming menù
TOUCH KNOB
Clockwise
Scroll through menù options
Increases values
Anti-clockwise
Scroll through menù options
Decreases values
ON/OFF
Press and release
ESC function
Press for at least for 3 sec
Turns instrument ON/OFF (Standby)
LIGHT
Press and release
Turn light ON/OFF
Содержание GM1
Страница 22: ...22 Door heater cable...
Страница 73: ...73 Cable resistencia puerta...
Страница 92: ......
Страница 93: ......