Installation
Straddle version:
before mounting the unit prepare the cuts and holes in the cold room wall shown in the picture.
Fix the unit in place with the appropriate screws. Position the unit on the cold room, connect the evaporator
drain tray spigot and the hole prepared in the cold room wall using the supplied fitting with pre-inserted
heater (for low temperature units only). Secure with the appropriate screw.
Fill the hole in the wall with insulating material, polyurethane or silicone, and mount the hole cover.
E
C
E
D
B
F
A
A
mm
B
mm
C
mm
D
mm
E
mm
F
a°
GM1
19
316
288
83
43
6
GM2
19
316
503
83
43
6
GM3-340
19
425
503
83
43
6
Thru-wall version (optional):
A)
Prepare a opening with suitable dimensions in the cold room wall (see picture).
B)
Position the unit onto the cold room wall inserting the evaporator section in the opening.
C)
Fix the unit using the screws supplied.
C
D
Inject silicone all
around the panel
opening
E
G
Condensate drain line Ø 14
Fitting
Condensate drain line Ø 28
Hole