8
1
Electrical Parameters
1-1
Rated solar panel short circuit current
40
Max.
AMP
1-2
Normal input Solar cell array voltage
15-22
VDC
1-3
Max. solar cell array voltage (output has no load)
25
Max.
VDC
1-4
The controller lowest operating voltage (solar or battery side)
8V
Min
VDC
1-5
Maximum voltage drop-Solar panel to battery
0.25
Max.
VDC
2
Charging characteristics
2-1
Minimum battery start charging voltage
3
Min
VDC
2-2
Soft start charging voltage
3-10
+/-0.2 VDC
2-3
Soft start charging current
Up to 20
AMP
2-4
Bulk charge voltage
10-14.0
+/-0.2 VDC
2-5
Absorption charging voltage at 25
℃
--LI-95 type battery
( i )
13.7
+/-0.2 VDC
--LTO type battery
14.0
+/-0.2 VDC
--Gel type battery
14.1
+/-0.2 VDC
--LiFePO4 battery
14.2
+/-0.2 VDC
--AGM type battery (default setting)
14.4
+/-0.2 VDC
--WET type battery
14.7
+/-0.2 VDC
2-6
Absorption transits to Equalizing or Float condition:
--Charging current drops to
1.0
+/0.1
AMP
-- or Absorption charging timer timed out
4
Hour
2-7
Equalization charging active
--Only for WET battery
--Battery voltage discharged to less than
10
+/-0.2 VDC
--Automatic equalizing charging periodical
28
Day
2-8
Equalization charging voltage at 25
℃
15.5
+/-0.2 VDC
2-9
Equalization charging timer timed out
2
Hour
2-10 Float charging voltage at 25
℃
-- For LI-95, LTO and LiFePO4 battery
13.4
+/-0.2 VDC
-- For Gel, AGM, WET, battery
13.6
+/-0.2 VDC
2-11 Voltage control accuracy
+/- 1%
2-12 Battery temperature compensation coefficient
-24
mV/
℃
2-13 Temperature compensation range
-20~+50
℃
3
Protection
3-1
Against reverse polarity or short circuit
3-2
No reverse current from battery to solar at night
3-3
Over temperature protection during charging
65
℃
3-4
Transient over voltage protection with TVS or varistor
4
Electrical parts
4-1
Input output terminal
M5 terminals
4-2
Remote port
RJ-11 (6 pins)
5
Physical Parameters
5-1
Controller material
Plastic, Standard ABS
5-2
Power terminal maximum stranded wire size
#6 AWG stranded-16 mm
2
5-3
Power terminal torque
Up to 17 in-lb (0.2n-m)
5-4
Mounting
Vertical wall mounting
5-5
IP grade
IP22,
5-6
Net weight
Approx. 0.3kg / 0.66lb
6
Environmental characteristics
6-1
Operating temperature
-25 ~ 50
℃
/ -13 ~ 122
℉
6-2
Storage temperature
-40 ~ 85
℃
/ -40 ~ 185
℉
6-3
Operating Humidity range
100% no condensation
Remarks: Voltage settings for 12V mode, x2 for 24V mode.
( i ) The LI-95 battery profile keeps your LiFePO4 battery charged at 95%. Evidence suggests
that charging your Lithium battery to less than 100% can increase longevity of your battery.