GB
ZAMEL devices marked with this
sign can work with each other
WORK
PROGR.
CHANNEL 1
Output
K1
Assembly of the
appliance can be
performed by a
person with
adequate
qualifications.
contact NO
Power supply
230V
wire gland
PG11
Round wire of diameter
from 4 ÷ 10 mm
Time adjustment
in the monostable
mode
Operating mode switch
monostable/bistable
BNC50 aerial socket
WORK
[P-PRACA]
jumper contacts
PROGRAMOWANIE
[P-PROGRAM]
jumper contacts
1 KANAŁ [1 CHANNEL]
An exemplary solution of the control system for four independent receivers
(1-phase motors) with the RWS-211J/N device.
WARNING! Please keep in mind that the terminals of K1 relays
are volt-free, so one of poles shall be supplied with phase potential.
ONE-CHANNEL RADIO POWER SWITCH RWS-211J/N
•
Remote controlled switch for switching on / off household electrical appliances such as: lighting,
heaters, fans, air conditioners, pumps, gates, barriers, optical and acoustic signalling systems,
•
Radio transmission (frequency of 433.92 MHz);
•
Operating range: 300 m* in open area
•
Encoding: KEELOQ rolling code,
•
Adapted to operate in changeable weather conditions,
•
Convenient for remote control of not easy accessible devices,
•
Effective support for the maintenance services and security,
•
Perfect aid for the handicapped,
•
The device connected directly to 230 VAC outlet socket
•
The remote control battery-operated,
•
Possibility to operate with the P-258/2, P-258/4, P-259/8 and P-207/2 remote controls of
ZAMEL,
•
Ability to control a single receiver with a single remote control,
•
Possibility of operation of many (up to 113) remote controls with a single receiver,
•
Designed for continuous running,
•
Possibility of the operating range increase by means of the RT-219 retransmitter of ZAMEL.
TECHNICAL SPECIFICATIONS
Transmitter (P-258/2 remote control)
Power supply: DC 12 V battery (4xCR 2016)
Operating frequency: 433,92 MHz
IP protection: IP20
RF Power: < 5 mW
Operating range in open area 300 m*
Temperature operating range: from 0º C to + 35ºC
SINGLE-CHANNEL RECEIVER
Power supply: 230 VAC / 50 Hz
Power consumption: 3 VA
Relay load: 16 A / 250 VAC / AC1
Radio transmission encoded
Operating frequency: 433,92 MHz
Antenna socket: BNC 50
Operating range in open area: according to the following table
The number of channels: 1
The number of remote controls included: 1
The number of remote controls to be entered: 113
Sensitivity: –105 dBm
Operating modes: bistable, monostable with smooth adjustment of the operating time from 1 s to 2 min.,
for each channel independently adjustable
Coding: KEELOQ rolling code
Protection level: IP56
Temperature operating range: - 20º C to + 35ºC
Protection class: II
Dimensions [ mm]: 127 x 120 x 60
COOPERATION AND OPERATING RANGE*
* The operating range given above, concerns the open area under ideal conditions, with no obstacles.
If there are obstacles between the receiver and the transmitter, one should expect a decrease in the
operating range for, respectively: wood and plaster by 5 to 20%, brick by 20 to 40%, reinforced concrete
by 40 to 80%. It is not reco mmended to use the radio systems in case of metal obstacles, due to a
significant limitation of the operating range. Also aerial and underground power engineering lines of a
large power capacity and GSM transmitters in close proximity of these devices have a negative impact
on their operating range.
GENERAL DESCRIPTION
The microprocessor radio power switch RWS-211J/N is designed for remote (by radio) control of all
kinds of household electrical appliances (e.g. motors, lights, gates, garden and home lighting, pumps,
optical and acoustic signalling systems). In the appliance, there is the system of KELOOQ® rolling code
used, manufactured by Microchip Technology Inc. USA. Each transmission to the receiver is coded
dynamically, and each remote control has its own unique code, which provides the user with the highest
level of security. 433.92 MHz carrier frequency is used for the transmission between the receiver and
the transmitter. The receiver has an air-tight IP56 enclosure, and therefore can be used in all weather
conditions. The RWS-211J/N is designed for direct 230 VAC supply and can operate continuously. Low
power consumption (3 VA) makes this device suitable for the energy-saving solutions. The self-strip
terminal connectors are used for lead connection. 16 A / 250 VAC / AC1 relay is used as the device
output. The single-channel receiver includes a single track, with the possibility of the operating mode
setting (monostable / bistable) and smooth time adjustment in the monostable mode. The RWS-211J/N
set includes a single-channel receiver and the P-258/2 remote control. In addition, the RWS-211J/N
can operate with several types of the remote controls of ZAMEL: P-258/2 (two-button remote control
— key chain), P-258/4 (four-button remote control — key chain), P-259/8 (eight-button remote control),
P-207/2 (two-button remote control).
OPERATING MODES
● Bistable: switching on and off the relay of the RWS-211J/N comes after pressing the remote control
button stored previously in the receiver memory.
At the purchased device button 1 switches on and off the device.
● Monostable: switching on and off the relay of the RWS-211J/N comes after pressing the remote
control button stored previously in the receiver memory.
The relay is off automatically after the time set with the potentiometer in the RWS-211J/N device,
ranging from 1 second to 2 minutes. When the same button is pressed again during counting the time,
the time counting starts from the beginning.
DEVICE MOUNTING
1. Check if the supply voltage is in accordance with the device rated voltage: 230 V / 50 Hz.
2. Disconnect the device power supply by means of separating the circuit with an appropriate fuse or
removing the fuse [in case of the excess current flat circuit-breaker switch it to the OFF („0”) position].
3. NOTE! Check if the power supply circuit has been separated correctly by means of a voltage tester.
4. Unscrew 4 screws holding the receiver cover.
5. At the selected places on the wall drill two holes and insert the wall plugs into the holes.
6. After removing the top cover, remove the protective screw caps, make holes for the screws in the
enclosure, tighten the screws and attach the cover to the wall, and put caps on the screws (to protect
against getting water into the enclosure from the wall side).
7. Feed the wires through the cable glands into the receiver interior and tighten the glands.
8. Connect wires according to the electrical diagram.
9. Place the antenna.
10. Set the selected operating mode (bistable / monostable) with the receiver microswitch.
11. When the receiver operates in the monostable mode set the time with the potentiometer (1 s ÷ 2
min.).
12. Replace the cover and tighten the cover mounting screws, turn 230 VAC mains and check the
device functioning.
13. Each remote control of a new device is pre-progra mmed by the manufacturer.
NOTE! Only authorised technician is allowed to mount the device.
It is necessary to keep to the following reco mmendations during the device mounting:
● The receiver should be mounted as high as possible, the antenna up,
● There shall be no metal objects close to the antenna, and electrical cables shall be placed so that
they pass the antenna zone.
● If two or more receivers are to be mounted side by side, it is necessary to keep a distance of minimum
1 m between the devices,
● If possible, avoid the device mounting near strong radio transmitters, e.g. CB radio,
● It is reco mmended to use 0.5 – 2.5 mm ² wires, double insulated, for the device installation,
● It is necessary to protect the power supply circuit with an appropriate fuse or switch disconnector for
the circuit separating in case of overcurrent, and a double-pole switch with minimum 3 mm distance
between its contacts.
PROGRA MMING
A single receiver can operate with multiple (up to 113) remote controls.
If more remote controls are progra mmed the first one in entering into memory order will be erased
from the memory.
1. Turn off the power supply and check if there is no voltage on the terminals of the RWS-211J/N.
2. Put over the jumper from the „OPERATION” position into the „CHANNEL 1” position.
3. Turn on the power supply— the LED control should be lit.
4. Press and release any button of the remote control that is to switch on and off the RWS-211J/N.
5. When the LED goes out, press and release the same button of the remote control.
The LED will flash several times and then start to light continuously, waiting for the next remote control
enter.
The time between entering the consecutive remote controls must be less than 60 seconds. Otherwise,
all remote controls will be erased from the receiver memory.
The time is counted from the last key press.
6. After entering all remote controls turn off the power supply, check if there is no voltage on the
terminals and put over the jumper in the „OPERATION” position.
7. Turn on the power supply and check operation of the device by means of switching on and off the
receiver with the entered remote controls.
NOTE! A single blink of the LED indicates that an error has occurred and the entering process must
be repeated.
The receiver memory accepts only ZAMEL transmitters of Y series.
If you attempt to enter a third-party transmitter, the transmitter will be rejected by the receiver.
REmotE coNtRol ERasiNG FRom thE REcEivER mEmoRY
This procedure is to be performed in case of loss or theft of a remote control.
1. Turn off the power supply and check if there is no voltage on the terminals of the RWS-211J/N.
2. Put over the jumper from the „OPERATION” position into the „CHANNEL 1” position.
3. Turn on the power supply.
4. The LED control will light up continuously.
5. Do not touch any buttons for 60 seconds; the LED will go out when all remote controls are erased
from the receiver memory.
6. Turn off the power supply and check if there is no voltage on the terminals of the RWS-211J/N.
7. Put over the jumper into the „OPERATION” position.
8. Turn on the power supply and check if the erasing operation has been successful (none of the
previously progra mmed remote controls should operate).
9. After switching off the device, putting over the jumper into the „CHANNEL 1” position and turning on
the power supply the device will be ready for the new remote control progra mming.
The Declaration of Conformity is on our Website www.zamelcet.com
RWS-211J/N
RT-219 + RWS-211J/N
P-258/2
300 m
500 m
P-258/4
300 m
500 m
P-259/8
450 m
650 m
P-207/2
350 m
550 m
RWS-211J_N_inter.indd 4-5