220 ÷ 240 V~
OPERATION P-257/2
After pressing the push-button the remote control sends a signal on 868 MHz which controls
EXTA FREE receivers.
Device programming procedure (adding a transmitter to the trans-
mitter’s memory) is described in manual instruction of particular EXTA FREE system
receivers.
The range (up to 300 m depending on a receiver) can be changed by means of a retransmitter
or few RTN-01 retransmitters.
BATTERY CHANGE
Battery discharge status is signalled by several LED red diode flashes during transmis-
sion time.
1. Remove the screws from the bottom part of the remote control.
2. Remove the upper cover with the silicon keyboard.
3. Remove the battery from the latch.
4. Mount a new battery.
Watch battery polarisation marked on the latch. Wrong battery
mounting may cause device damage.
5. Place back the top cover with the keyboard and tighten the screws.
OPERATION, MOUNTING ROP-01
CONNECTION
1. Disconnect power supply by the phase fuse, the circuit-breaker or the switch-disconnector
combined to the proper circuit.
2.
Check if there is no voltage on connection cables by means of a special measure equip-
ment.
3. Connect the cables with the terminals in accordance with the installing diagram.
4. Install ROP-01 device in installation cable box.
5. Switch on the power supply from the mains.
The device can operate in five modes:
MONOSTABLE
the relay operates only while pressing transmitter’s push-button.
BISTABLE
(one push-button) the device changes relay status cyclically always after pressing
the same push-button.
SWITCH ON
the device switches on after pressing the push-button.
SWITCH OFF
the device switches off after pressing the push-button.
TIME
the device switches off according to the adjusted time (tp), but it may be switched off before
adjusted time finishes. Default settings - 15 seconds.
ATTENTION! Saved time will be not deleted.