TECHNICAL DATA
P-257/2
ROP-01
Input (supply) terminals:
-
L, N
Input rated voltage:
3 V (battery CR2032)
230 V~
Battery life:
3 ÷ 5 years
-
Input voltage tolerance:
-
-15 ÷ +10 %
Nominal frequency:
-
50 / 60 Hz
Nominal power consumption:
-
0,29 W
Number of operation modes:
-
5
Number of channels:
2
1
Maximum transmit power:
ERP<20 mW
-
Transmission:
radio 868 MHz
Transmission way:
unidirectional
Coding:
addressing transmission
Maximum number of transmitters:
-
32
Range:
up to 300 m
in the open area
up to 230 m
in the open area
Time adjustment:
-
1 s ÷ 18 hours (every
second)
Optical signalling:
LED red diode
Relay output clamps:
-
12, 11, 14
Relay contacts parameters:
-
1NO/NC 5A / 250V AC
AC1 1250 VA
Number of terminal clamps:
-
5
Section of connecting cables:
-
up to 2,5 mm
2
Ambient temperature range:
-10 ÷ +55
o
C
Operating position:
free
Mounting:
-
installation cable box
Ø60 mm
Casing protection degree:
IP20
Protection level:
III
-
Overvoltage category:
-
II
Pollution degree:
2
Surge voltage:
-
1 kV
Dimensions:
74 x 33 x 11,5 mm
47,5 x 47,5 x 20 mm
Weight:
0,020 kg
0,043 kg