DESCRIPTION

MAIN MENU

T1 AND T2 TIME ADJUSTMENT

EXTERNAL INPUT ADJUSTMENT

BACKLIGHT LEVEL ADJUSTMENT

Displayed elements and messages description

 - relay mode 

 

 - t1 and t2 time adjustment 

 

 - switch on/switch off

 - automatic mode 

 

 - 

operating mode adjustment

 - manual mode 

 

 - backlight level adjustment

 - external input S 

 

 - permanent switch on / switch off input

 - external input IN 

 

 - waiting for releasing signal

 - 

backlight

 

 

 - operating mode end

Push button description

 

 

• main window – automatic mode entry 

 

 

• main window – manual mode entry or relay mode change if the clock is already in the manual mode

 

  • main window – main menu entry

   

• different windows - submenu entry or adjusted value confirmation

 

  • menu windows/options change or decreasing/increasing the adjusted value 

Choose OK to enter menu; use cursor   to choose options.

 

Function  Description

 

 

OPERATING MODE ADJUSTMENT

 

  T1 TIME ADJUSTMENT

 

 

T2 TIME ADJUSTMENT

 

 

EXTERNAL INPUT ADJUSTMENT

 

 

BACKLIGHT LEVEL ADJUSTMENT

 

 - 

 time preview and adjustment; press OK to enter;

 

 adjusted time preview window, press OK to enter;

 HOUR - use cursor   to choose the required number of hours; adjustment range from 0 to 99; press OK to confirm;

 MINUTE - use cursor   to choose the required number of minutes; adjustment range from 0 to 59; press OK to confirm;

 SECOND - use cursor   to choose the required number of seconds; adjustment range from 0 to 59; press OK to confirm;

 DECIMAL POINT OF A SECOND - use cursor   to choose the required value; adjustment range from 0 to 90; press OK to confirm;

 To confirm all the adjustments press OK; confirming the command allows to enter the time adjustment window.

The system is equipped with protection against 0h0m0s0ss - 0,1 sec is the minimum time.

 time adjustment in 

 menu - similarly to 

 menu.

 

  -  system  mode  adjustment  suitable  for  the  moment  of  releasing 

external input IN; the system operates in this mode as long as there is a 

releasing signal on external input IN; press OK to enter; use cursors   to 

choose a suitable mode for the external input, where:

 

 - external input function is switched off;

   

 - manual mode with a relay constantly switched off;

   

 - manual mode with a relay constantly switched on;

Use cursors   to change options; press Ok button to confirm choices.

After the signal in releasing input IN disappears, the previous operating mode 

(time measure) will be finished.

There is an escape possibility from every submenu window one level high-

er in every moment of programming by pressing   or   without saving the 

adjusments.

 

 - backlight level adjustment; press OK to enter;

 

 - the backlight switches on after pressing any of the buttons, and it will 

be switched off automatically after 20 seconds from the last press;

 

 - the backlight will be switched on as long as the system is connected to 

power supply voltage;

 

 - the backlight will be switched off.

Use cursors   to change options; press OK to confirm your choices.

There is an escape possibility from every submenu window one level higher 

in every moment of programming by pressing   or   without saving the 

adjusments.

There is an escape possibility from 

every  submenu  window  one  level 

higher in every moment of program-

ming by pressing   or   without sav-

ing the adjusments.

Содержание PCM-07/U

Страница 1: ... The multifunctional digital time relay PCM 07 U has a time function in automa tion and control systems It is equipped with 25 independent operating modes released by power supply voltage or an external impulse command on S terminal coming from L or N line It has a really wide time adjustment range from 0 1 sec to 99 h 59 min 59 9 sec And it has per manent switch on switch off functions by means o...

Страница 2: ... to confirm To confirm all the adjustments press OK confirming the command allows to enter the time adjustment window The system is equipped with protection against 0h0m0s0ss 0 1 sec is the minimum time time adjustment in menu similarly to menu system mode adjustment suitable for the moment of releasing external input IN the system operates in this mode as long as there is a releasing signal on ex...

Страница 3: ...ggerable SWITCH ON OFF DELAY non retriggerable after the impulse release has been applied to the power supply system rising edge it lets the relay be switched off pos 11 12 at the same time starts the preset time t1 measurement After the time is over the relay is swit ched on pos 11 14 After the impulse release fade is detected falling modulated voltage the system starts preset time t2 measuremnt ...

Страница 4: ...unction box Ø60 version Device symbol The main switch L N The acoustic signal system of starting the machine engine Operating adjusted to WARRANTY CARD There is 24 months guarantee on the product Salesman stamp and signature date of sale 1 ZMIE ZAMEL SP J assures 24 months guarantee for the product 2 The manufacturer s guarantee does not cover any of the following actions a mechanical damage durin...

Отзывы: