background image

*apply to the product ZCM-22P/U

ZCM-22, ZCM-22P/U 

TIME PROGRAMMER

ANNUAL, SINGLE-CHANEL

 

INSTRUCTION MANUAL

ZAMEL 

sp. z o.o.

ul. Zielona 27, 43-200 Pszczyna, Poland

tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04

www.zamel.com

, e-mail: [email protected]

*apply to the product ZCM-22P/U

CONNECTION*

PRODUCT FAMILY

ZCM-22 Programmer belongs to ZCM 

family of products.

MOUNTING, OPERATION

1.  Disconnect power supply by the phase fuse, the circuit-breaker or the switch- disconnector combined to the proper 

circuit.

2.  Check if there is no voltage on connection cables by means of a special measure equipment.
3.  Install the ZCM-22 on the TH 35 DIN rail in the switchboard.
4.  Connect the cables with the terminals in accordance with the installing diagram.
5.  Switch on the power supply from the mains.

The contact will be ON at 00:00:00. The contact will be OFF the previously set day during an hour changing from 
23:59:59 into 00:00:00 (the next day).  If the contact is to be ON only one day, the same data should be set for ON and 
OFF date, e.g.   ON - 02.02, OFF - 02.02. The lower program no. the higher program priority. The ON state has higher 
priority than the OFF state within the given program.

INNER DIAGRAM

RELAY CAPACITY

DIMENSIONS

EXTERNAL MEMORY OPERATION*

External memory allows for an easy record / reading of the adjusted programs into 

the external memory, so they can be easily  copied to other programmers. It is very 

convenient in case if we want to program more ZCM programmers or archive the 

adjusted programs.

 

 – sub menu to the external memory operation 

 

 – programs recording

 

 – programs reading from the external memory and storage in the program-

mer’s memory 

 

 – the state of memory „busy” during a record / reading 

 

 – correct record / reading

 

 – record /reading error 

APPEARANCE*

FEATURES

TECHNICAL DATA

DESCRIPTION

ZCM-22, ZCM-22P/U

Power supply clamps:

A1, A2

Rated voltage: ZCM-22: 230 V AC

~

(-15 ÷ +10 %) 

ZCM-22P/U: 24 ÷ 250 V AC, 30 ÷ 300 V DC

Rated frequency:

50 / 60 Hz

Rated power consumption:

ZCM-22: 1,6 W /17 VA    ZCM-22 P/U: 1,5 W /3 VA

 Number of channels:

1

Program quantity: 400 (200 On/Off pairs)

Programme:

weekly - annual

Mode of work: manual, automatic

Change of season summer/ winter: automatic, manual

Colour of LCD panel lighting: amber

Input: yes

Accuracy of time measurement: max. ±1 s / 24  h at temp. 25 °C

Time of clock maintenance: 3 years

Time of programme maintenance: 10 years

Clamps of release system:

IN, IN, IN, IN

Clamps of receiver power supply:

11, 12, 14

Parameters of transmitter contacts:

1NO/NC-16 A/250 V AC1 4000 VA

Number of terminating clamps: 12

Intersection of terminating conductors: 0,2 ÷ 2,50 mm

2

Temperature of work: -20 ÷ +60 

o

C

Position of work: any

Fixing of casing: TH 35 rail (PN-EN 60715)

Level of protection of casing: IP20 (PN-EN 60529)

Protectivity class: II

Overvoltage category: II

Level of pollution: 2

Measurements: two-module (35 mm) 90x35x66 mm

Weight: 0,14 kg

Compatibility with norms: PN-EN 60730-1; PN-EN 60730-2-7; 

PN-EN 61000-4-2,3,4,5,6,11

●  Control depending on current date, 

hour and minute,

●  double-module casing with a protec-

tion flap,

●  additional control input IN,

●  many programmes enabling various 

applications,

●  LCD display illumination,

●  mounted on TH 35 rail,

●  a possibility to copy and read pro-

grams from the external memory*.

Digital control time switch ZCM-22 is used 

to realise the time functions in automation 

and control systems. The programmer re-

alises the output relay control operations 

according to program adjustments (day, 

month, hour, minute). All systems are 

equipped with a control input function, 

which is used to change the operating 

mode of a system by means of an exter-

nal push-button. The design of the cas-

ing allows the system to be mounted on a 

TH-35 rail and eventually to seal the de-

vice. The design of the system provides 

a battery back-up system for all adjust-

ments in case of no voltage supply.

In order to protect the battery during 

storage, the ZCM series programmers 

have a default setting, the so-called 

storage mode in which the battery 

power consumption is limited to a mini-

mum.

The device should be connected 

to a singlephase system ac-

cording to current standards. 

The device connections will be 

described in this manual. Only 

qualified electricians are allowed 

to mount, connect and adjust the 

device. It is necessary to read 

this manual and know the unit functions before the 

device mounting. Do not disassembly the device 

casing or you will lose any warranty rights and ex-

pose yourself to the electric shock hazard. Before 

mounting operation make sure of disconnecting 

the connection wires from the electric network. 

Use a cross-head screwdriver of 3.5 mm diameter 

to mount the device. The relay should be carried, 

stored and used in an appropriate way. Do not 

mount the device in case of any device parts lack, 

damage or deformation. In case of malfunction 

please notify the manufacturer.

CAUTION

plik: zcm-22_pu_bateria_inst_ext_gb | modyfikacja: 28.10.2019

WARRANTY CARD

There is 24 months guarantee on the product

Salesman stamp and signature, date of sale

1.  ZAMEL provides a two-year warranty for its products. 

2.  The ZAMEL warranty does not cover: 

  a) mechanical defects resulting from transport, loading / unloading or other circumstances 

  b) defects resulting from incorrect installation or operation of ZAMEL products; 

  c) defects resulting from any changes made by CUSTOMERS or third parties, to products sold or equipment necessary for the correct 

operation of products sold; 

  d) defects resulting from force majeure or other aleatory events for which ZAMEL is not liable; 

  e) power supply (batteries) to be equipped with a device in the moment of sale (if they appear); 

3.  All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect.; 

4.  ZAMEL will review complaints in accordance with existing regulations.; 

5.  The way a complaint is settled, e.g. replacement of the product, repair or refund, is left to the discretion of ZAMEL. 

6.  Guarantee does not exclude, does not limit, nor does it suspend the rights of the PURCHASER resulting from the discrepancy be-

tween the goods and the contract.

Programmer type:

11 - week (1 channel)

12 - week (2 channel)

31 - astronomical

Device type

Power supply:

ZCM-xx -  230 V AC

ZCM-xx/U -  24 ÷ 250 VAC

 

30 ÷ 300 V DC

22 - weekly - year

Winter time

Summer time

Manual mode

Automatic mode

Week’s day

Relay state

Info field

Current time
(gg:mm:ss)

Power terminals

(A1, A2)

LCD display

External memory*

Replaceable battery

Control buttons

Relay output terminals
(12, 12, 11, 11, 14, 14)

Trigger terminals

(IN, IN, IN, IN)

L(+)

L(+) / N(-)

N(-)

Do not dispose of this device with other 

waste! In order to avoid harmful effects 

on the environment and human health, 

the used device should be stored in 

designated areas. For this purpose, you 

can dispose of household waste free of 

charge and in any quantity to a collection 

point set up, as well as to the shop when 

you buy new equipment.

Отзывы: