background image

Moreover, during the first hours of operation of the fireplace, no objects 

shall be placed on it and the outer paint layer of the fireplace shall not be 

touched. The paint layer that has not set yet could be damaged by touch.

Before firing, all regulators shall be opened to the maximum. Concomitantly, 

air intake shall be ensured in the room. Fire can now be ignited with firing 

cubes, paper or wood chips. Never use gas, alcohol, petrol, etc. Place 

now the first layer of wood or a quantity of briquettes, respectively wood 

briquettes, on the lively-burning fire. Place the combustible materials in 

one single layer.

Optimum capability will not be reached at powers set too low, which 

generates high heating costs. Long-term use with low power results in the 

formation of a layer of smoke in the fireplace, particularly on the window. 

When used with nominal power, depositions are at a minimum. At too 

high powers, there is a danger of overheating the fireplace. Shortly, it will 

deteriorate. In this case, the manufacturer’s warranty is no longer valid.

4.3  

Recharge with fuel and proper use of the command devices 

 

and regulators

  

For optimum operation of your fireplace, it is very important that 

you observe the recharge periods and recommended fuel charge. 

 

Exceeding the charge burden overheats the fireplace and inevitably 

generates malfunctions, such as cracks in the refractory plates inside the 

furnace, deformation of the fireplace, deterioration of the grill, etc. 

 

The overheating danger is excluded if the nominal heating power is not 

exceeded.

The recharge burden with fuel has the following values:

• wooden blocks – 1.5 kg

• compressed, untreated wooden blocks – 1.3 kg

Fireplaces are equipped with the following burning regulators:

• primary air regulator, the operation handle of which is found beneath  

   the door (upper side of the wood compartment);

• secondary air regulator, the operation button of which is found on the door

• in the upper side of it (valid for Goliath furnace)

• flue gas regulator the handle of which is found above the door (for    

   Goliath furnace)

  

The primary air regulator provides air for burning the solid fuel. The primary air 

goes through the grill and through the fuel charge. 

The flue gas regulator has a role in regulating the draft on the chimney stack 

and has effect on the fuel consumption. 

5.  

IMPORTANT INDICATIONS FOR EXPLOITATION AND SAFETY

 

5.1  

Normal operation and proper burning

Optimum adjustment of the burning process requires experience, particularly 

when the chimney draft is not constant or, for instance, wood of different quality 

is used.

In order to prevent uncontrolled burning through too high air intake, which 

would bring the fireplace to high temperatures very quickly, please make sure 

that you never warm:

• with the ash bin door opened;

• with the flap-shutter opened during unfavorable time;

• with too strong chimney draft.

9

8

WARNING! 

 

Improper use of air regulators and, particularly, 

of the primary air regulator can damage the fireplace.

Содержание Hercules

Страница 1: ...goliath hercules fortuna SOLID FUEL FIREPLACES User Guide...

Страница 2: ...lace the most important of which is presented below Remember that your fireplace should not be used as a sole source for heating on the long term It is designed to support your existing heating system...

Страница 3: ...e used The use of wet wood is not allowed because it can generate smoke 3 2 CUPRINS 1 INTRODUCTION 2 COMPONENTS AND TECHNICAL CHARACTERISTICS 3 INSTRUCTIONS FOR USE 3 1 General instructions for instal...

Страница 4: ...d speed residues on the stack etc 3 2 The floor and necessary safety distances to combustible materials The floor must be able to withhold the weight of the fireplace If the floor is made from combust...

Страница 5: ...eased when specific materials are burnt which damage health and the environment burning the following materials in the fireplace shall be banned varnished wood covered in a layer of plastic material o...

Страница 6: ...side the furnace deformation of the fireplace deterioration of the grill etc The overheating danger is excluded if the nominal heating power is not exceeded The recharge burden with fuel has the follo...

Страница 7: ...heat delivery of the fireplace A stronger chimney draft requires smalleroutlets whilealowerdraftrequireslargeroutletsoftheairregulator As the fireplace heats significantly be careful when you open th...

Страница 8: ...ll be delivered to specific units to contribute to environmental protection In order to have the emissions of flue gas fall within the limits admitted by the national and European regulations only fue...

Страница 9: ...shall be made in packages in dry rooms not exposed to potential mechanical blows protected against wetness and chemical and corrosive agents Nonconformities resulting from improper transport handling...

Страница 10: ...r potential inaccuracies contained in this manual if owed to printing or transcription errors We reserve the right to bring to our products any change arising to be necessary or useful without prejudi...

Страница 11: ...he technical data is informative Zaconex reserves the right to make changes in the range Contact information Harman Brasov County 327 Mihai Viteazul Tel Fax 40 268 367 560 40 722 553 020 www zaconex r...

Отзывы: