2.
COMPONENTS AND TECHNICAL CHARACTERISTICS
3.
INSTRUCTIONS FOR USE
1.
General instructions for installation
a.
Your fireplace requires a chimney stack. We can guarantee safe
operation and nominal heating power only when the sufficient technical
capacity of the stack is proven and was confirmed by the chimney stack
master.
Most often, the fireplace may be connected directly to the stack. If, however,
the stack draft is reduced, it is better for the fireplace to be connected to
the stack through a vertical gas exhaust tube, serving as an acceleration
route.
Only flue gas exhaust tubes shall be used. Take into account that, in order
to avoid pressure losses, the gas exhaust tube must be as short as possible,
straight and slightly ascendant. Moreover, the tube sections shall be installed in
a rigid and tight way.
WARNING!
No more than two recovery units may be connected
to the stack provided for connection with the fireplace.
b.
Only the sweeper may check if a reduction of the connection
piece or of the stack is sufficient, respectively, if the reduction draft for
fireplace exploitation is sufficient and admissible. In case of reduction, the
manufacturer may no longer guarantee flawless exploitation of the fireplace.
c.
The stack draft can be very differently influenced throughout a one-year
period and depends on various variable factors, such as, temperature of the
outer environment, temperature of the exhaust gas, wind speed, residues on the
stack, etc.
3.2. The floor and necessary safety distances to combustible materials
The floor must be able to withhold the weight of the fireplace. If the floor is made
from combustible material (for instance parquet), this must be protected with
incombustible and insulating material, placed beneath and around the fireplace
on a surface large enough to provide safety in exploitation. In this regard, we
recommend Zaconex-branded fireplace supports.
3.3.
Rules for the installation place
The room where the heating system will be installed cannot contain
other equipment using the same principle of operation if they do not
use outside air for combustion, for instance. Under no circumstances
can they be installed in places where machinery with natural
draft, heating pumps or collective air pipes are or will be presented.
5
4
fontă
10/12
40
mp
lemn
90
Weight
Power
Chimney surface
Hot air gates
Fuel
Door opening
Combustion air
Installation options
Installation
Hot air exhaust
Warranty
Ironware
Made in Romania
Bestseller in Romania
and in Germany
90 kg
10 (12) kw
200 - 250 cm
3
2
wood
left / right
interior
without recovery unit (10 kW)
with recovery unit (12 kW)
straight/corner
-
-
5 years
gold/silver
134 kg
11 (13) kw
200 - 250 cm
3
2
wood
left / right
interior
without recovery unit (11 kW)
with recovery unit (13 kW)
pe plan drept / pe colț
-
-
5 years
-
-
114 kg
12 kw
250 - 300 cm
3
1
wood
left / right
lateral
without recovery unit (11 kW)
with recovery unit (13 kW)
pe plan drept / pe colț
4 x 150 cm
exterior
5 years
black/premium
-
goliath
hercules
fortuna
SoliD fUel
fireplaCe
fontă
11/13
80
mp
lemn
134
12
120
mp
lemn
114
oțel
șamotă