The position encoder has de-synchronized.
Reset the device by power cycling it or sending the
system reset
(
T:0
) command, then re-
initialize it with the
home
(
T:1
) command.
The device is moving very slowly. It used to move faster.
The speed settings may have been changed inadvertently.
Send a
system restore
(
T:36
) command.
The device makes louder than normal noise during travel and is frequently slipping.
This condition happens if the thrust needed is more than the thrust available from the device.
Check the following:
The force on the device is less than the maximum thrust.
The voltage matches the specified voltage. Read the voltage using the
get
system.voltage
command. Voltage less than the specified voltage for the device will
reduce the device’s maximum thrust.
Test the following:
Try a slower target velocity. Stepper motors produce more thrust when moving slowly.
Try a lower acceleration and deceleration.
Clean the screw and lightly re-grease it with a grease that does not degrade plastics.
The device has repeatability errors smaller than 4 full steps.
If steps aren't being skipped, friction or loose parts may still cause some variation when
returning to a position.
Please contact
Zaber Technical Support
.
The device doesn't cover the full range of travel, or runs into the end.
A setting might have been inadvertently changed.
home
(
T:1
) the device to see if this corrects the behaviour.
Send a
system restore
(
T:36
) command.
The device's motor unexpectedly shuts off. An
Fx warning flag
is present.
The motor over-temperature protection switch has been tripped. This sensor will trip if the
device's maximum continuous thrust specification is exceeded for too long. To prevent this
condition from occurring again, reduce the average force that the motor outputs by reducing
acceleration, reducing the load, or lowering the duty cycle.
Send a
driver enable
command. The device does not require homing.
Communication Errors
There is no communication with the device; the Yellow LED does not come on or flash.
There are several things that should be checked:
Make sure the correct serial port is selected. Try selecting other serial ports in the
software.