(3) Take the HDMI cable connected to the monitor and connect it to HDMI In of the board.
(4) Connect the Ethernet of the board to either your PC or a hub your PC is connected to.
The next step is to set up a terminal to view the activity of the board …
5.3 Set up the Terminal Window
(5) If you are running from a Windows PC, run TeraTerm. Select
“Setup – Serial Port” and set the
following:
Port:
Whichever serial port the port is connected to
Baud Rate: 115200
Data:
8-bit
Parity:
None
Stop:
1-bit
Flow Control: None
(6) If you are running from Linux, type:
# sudo minicom –s
And then configure by doing the following:
-Select “Serial Port Setup”
-Ensure the correct Serial Device is specified (typically “/dev/ttyUSB0”)
-Set option E (“Bps/Par/Bits”) to 115200 8N1
-Press <return>
-Select “Exit”
5.4 Power on the board
(7) Connect the 12V power supply and turn on the switch. If all is configured properly, you should see the
board booting up within the terminal window. After about a minute, you will see the RPS Main Menu.
Note the local IP address and netmask (in this example, it is 192.168.81.68 and 255.255.0.0). This is
the IP address of the board. You will need this later to access the web interface.