(31)
If you select the Z3-DM368-RPS row and double-click on it, an Internet browser is opened at that
address to make the main menu appear:
(32)
You can go back to Static IP by unchecking “Use DHCP” and saving that to the user settings.
7.10
Dynamically Changing Bit Rate/ Frame Rate
It is possible to change two parameters in the middle of an encoding session:
(1) Video Bit rate
(2) Frame Decimation
To change these, simply enter the new desired value and then click the “Start Encoder” button.
The web page will respond with the following message:
Status: Changed rate
The video stream will then continue uninterrupted with the new parameter.
New IP Address