28
RabbitCore RCM3600
4.3 Programming Port
The RCM3600 programming port is accessed through header J2, and uses the Rabbit
3000’s Serial Port A for communication. Dynamic C uses the programming port to down-
load and debug programs.
The programming port is also used for the following operations.
•
Cold-boot the Rabbit 3000 on the RCM3600 after a reset.
•
Remotely download and debug a program over an Ethernet connection using the
RabbitLink EG2110.
•
Fast copy designated portions of flash memory from one Rabbit-based board (the
master) to another (the slave) using the Rabbit Cloning Board.
4.3.0.1 Alternate Uses of the Programming Port
All three clocked Serial Port A signals are available as
•
a synchronous serial port
•
an asynchronous serial port, with the clock line usable as a general CMOS input
The programming port may also be used as a serial port via the
DIAG
connector on the
programming cable.
In addition to Serial Port A, the two Rabbit 3000 startup-mode ( SMODE0, SMODE1),
status, and reset pins are available on the programming port.
The two startup mode pins determine what happens after a reset—the Rabbit 3000 is
either cold-booted or the program begins executing at address 0x0000.
The status pin is used by Dynamic C to determine whether a Rabbit microprocessor is
present. Since the status pin is not used by the system once a program has been down-
loaded and is running, the status pin can then be used as a general-purpose CMOS output..
The reset pin is an external input that is used to reset the Rabbit 3000..
Refer to the
Rabbit 3000 Microprocessor User’s Manual
for more information.
Содержание RabbitCore
Страница 1: ...RabbitCore RCM3600 C Programmable Core Module User s Manual 019 0135 050630 C ...
Страница 6: ...RabbitCore RCM3600 ...
Страница 12: ...6 RabbitCore RCM3600 ...
Страница 92: ...86 RabbitCore RCM3600 ...
Страница 128: ...122 RabbitCore RCM3600 ...
Страница 132: ...126 RabbitCore RCM3600 ...
Страница 136: ...130 RabbitCore RCM3600 ...
Страница 138: ......