![Z-Wave ZTS-500 Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/z-wave/zts-500/zts-500_user-manual_916497029.webp)
29
in motel service, advance user
or administrator can limit the
lower cool set point)
Example 68
o
F; input = 680 (0x02A8)
Unit in C:
Range from (5
o
C + dead band) to 37
o
C
Default = 7
o
C
Example 20
o
C; input = 200 (0x00C8)
Reset filter counter
7 (0x07)
0 (0x00) (default)
Set filter counter
8 (0x08)
500 (0x01F4) to 4000 (0x0FA0) hours
500 (0x01F4) hours (default)
Resolution = 1 (0x0001) hours
Report filter counter
(read only)
9 (0x09)
0 (0x0000) to 9999 (0x270F) hours
Sensor temperature calibration
(This parameter is used to
change the display temperature
to match with your previous
thermostat, or to match
another thermostat already in
your home.
10 (0x0A)
Temperature offset value.
Formula:
Display temperature = sensor reading value +
offset value
(unit = degree F)
0 (0x00) = 0
o
F (Default)
1 (0x01) = 1
o
F (0.5
o
C)
2 (0x02) = 2
o
F (1.0
o
C)
3 (0x03) = 3
o
F (1.5
o
C)
4 (0x04) = 4
o
F (2.0
o
C)
5 (0x05) = 5
o
F (2.5
o
C)
6 (0x06) = 6
o
F (3.0
o
C)
7 (0x07) = 7
o
F (3.5
o
C)
8 (0x08) = 8
o
F (4.0
o
C)
9 (0x09) = 9
o
F (4.5
o
C)
10 (0x0A) = 10
o
F (5.0
o
C)
-1 (0xFF) = -1
o
F (-0.5
o
C)
-2 (0xFE) = -2
o
F (-1.0
o
C)
-3 (0xFD) = -3
o
F (-1.5
o
C)
-4 (0xFC) = -4
o
F (-2.0
o
C)
-5 (0xFB) = -5
o
F (-2.5
o
C)
-6 (0xFA) = -6
o
F (-3.0
o
C)
-7 (0xF9) = -7
o
F (-3.5
o
C)
-8 (0xF8) = -8
o
F (-4.0
o
C)
-9 (0xF7) = -9
o
F (-4.5
o
C)
-10 (0xF6) = -10
o
F (-5.0
o
C)
LED brightness level
11 (0x0B)
1 (0x01) = Level-1 (dark)