4
-
The “
✔
” symbol will be displayed on screen
once the ZTS-500 is excluded from the network.
The Z-Wave disconnect icon will also be
displayed in the standby screen.
-
The “x” symbol will be displayed on screen if
there is no action (time out) or unable to
exclude the ZTS-500 from the network.
Note:
All Z-Wave configuration parameter values will keep no changes after excluding the unit from the
network, except for the association groups information. The ZTS-500 will retain the last selected
HVAC system type.
Support for Association Groups
ZTS-500 supports 3 association groups:
Association group_1
(Auto Report)
Association group_2
(Heater)
Association group_3
(Compressor)
Heating mode
-
ON
(basic set command 0xFF)
OFF
(basic set command 0x00)
Cooling mode
-
OFF
(basic set command 0x00)
ON
(basic set command 0xFF)
OFF
-
OFF
(basic set command 0x00)
OFF
(basic set command 0x00)
Association group_1 (Auto report):
Association Group-1 is a default status report channel in Z-Wave+ lifeline requirement.
ZTS-500 will trigger AUTO report function if one of below status is changed.
a)
Operation mode (Off, Heat, Cool, Auto)
b)
Operation state (Heat on or off, Cool on or off)
c)
Fan mode (Auto, On, High, Low)
d)
Fan state (Fan on, Fan off)
e)
Heat set point (report in precision of 0.5
o
C or 1
o
F)
Association group
Mode