![Z-Wave ZTS-500 Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/z-wave/zts-500/zts-500_user-manual_916497010.webp)
10
Do not split RC/RH for Heat Pump systems!
Single-stage: 1 Heat / 1 Cool
Figure 11. Heat pump HVAC system wiring
2-wires system with 1 heat only
Do not split RC/RH for Heat Pump systems!
For heat pump output, there is a 3 minutes off time for heat pump protection!
Figure 12. Heat pump 2-wires HVAC system wiring
Yellow
W1
W2
O
B
G1
G2
Y1
Y2
C
RC
RH
Black
(with C-Wire)
Red
Yellow
O - Cool changeover (heat pump)
B - Heat changeover (heat pump)
G - Fan
Y - Compressor (Heat/Cool)
C - 24Vac Common
R - 24Vac Power
Heat Pump HVAC System
Blue
Orange
ZTS-500
Green
W1
W2
O
B
G1
G2
Y1
Y2
C
RC
RH
Y - Compressor (Heat)
R - 24Vac Power
ZTS-500
(Powered by batteries)
Red
Heat Pump System
Typical wire colour
Typical wire colour
No C-wire
RC and RH are
internal connected
RC and RH are
internal connected