Z-Wave PST02-A Скачать руководство пользователя страница 9

NO.

Name

Def.

Valid

A B C

Description

2 Basic Set 

Level

0xFF

All

  

Setting the BASIC command value to 
turn on the light. The 0xFF(-1) means 
turn on the light. For dimmer 
equipment 1 to 100 means the light 
strength.
0 means turn off the light.

Caution

: The value is unsigned byte, 

the range is from 0x00 ~ 0xFF.

3

(*)

PIR 

Sensitivity

80

0 ~

99

  

PIR sensitivity settings.
0 means disable the PIR motion.
1 means the lowest sensitivity,
99 means the highest sensitivity.
High sensitivity means can detected 
long distance, but if there is more 
noise signal in the environment, it will 
re-trigger too frequency. 

4 Light 

Threshold

99

0 ~

100

  

Setting the illumination threshold to 
turn on the light. When the event 
triggered and the environment 
illumination lower then the threshold, 
the device will turn on the light.
0 means turn off illumination detected 
function. And never turn on the light.
1 means darkest.
99 means brightest.
100 means turn off illumination 
detected function. And always turn on 
the light.

Notice:

 In none test mode, only the 

value in 1 to 99 will enable the 
illumination detected function and 
update the illumination value.

NO.

Name

Def.

Valid

A B C

Description

5

(*)

Operation

Mode

0

All

Operation mode. Using bit to control.

Caution

: The value is unsigned byte, 

the range is from 0x00 ~ 0xFF.

0

  

Bit0

: Reserve.

0

  

Bit1

: 1 means test mode, 

        0 means normal mode.

Notice: 

This bit only effect by the DIP Switch 
setting to “customer mode”, otherwise 
it decides by DIP Switch setting to Test
or Normal Mode.

0

  

Bit2

: Disable the door/window 

function.  (1:Disable, 0:Enable)

0

  

Bit3

: Setting the temperature scale.

  0: 

Fahrenheit

, 1:

Celsius

0

  

Bit4

: Disable the illumination report 

after event triggered.  (1:Disable, 
0:Enable)

0

  

Bit5

: Disable the temperature report 

after event triggered.  (1:Disable, 
0:Enable)

0

  

Bit6

: Reserve.

0

  

Bit7: 

Disable the back key release 

into test mode.  (1:Disable, 
0:Enable)

9

Содержание PST02-A

Страница 1: ...TM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external i...

Страница 2: ...send the Basic Set command to this group And each group support 8 nodes maximum Failed or success in add remove the node ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM dev...

Страница 3: ...led to disable this function by setting the configuration NO 21 to 0 In the default when the temperature is changed to plus or minus one degree Fahrenheit 0 56 degree Celsius the device will report te...

Страница 4: ...ion Power Up Procedure Battery Power Check When the device power up the device will detect the power level of the battery immediately If the power level is too low the LED will continue flash about 5...

Страница 5: ...unction when installation Normal Mode for the normal operation When the event triggered normally the LED won t indicated unless the battery is in the low level the LED will flash once But in the Test...

Страница 6: ...6...

Страница 7: ...elease the cover 2 Hold the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push th...

Страница 8: ...nafter referred to as A tape and another is thinner hereinafter referred to as B tape you can use A tape for the test at the beginning The right way for A tape installation is stick it to the position...

Страница 9: ...tected function And never turn on the light 1 means darkest 99 means brightest 100 means turn off illumination detected function And always turn on the light Notice In none test mode only the value in...

Страница 10: ...people in that room 0 Bit4 Disable delay 5 seconds to turn off the light when door window closed 1 Disable 0 Enable 0 Bit5 Disable auto turn off the light after door window opened to turn on the light...

Страница 11: ...he interval time for auto report the door window state 0 means turn off auto report NO Name Def Valid A B C Description Time door window state The default value is 12 The tick time can setting by the...

Страница 12: ...NSOR_MULTILEVEL_V5 COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD COMMAND_CLASS_SECURITY COMMAND_CLASS_...

Страница 13: ...ures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver i...

Отзывы: