Z-Wave PST02-A Скачать руководство пользователя страница 10

NO.

Name

Def.

Valid

A B C

Description

6

(*)

Mult-

Sensor 

Function 

Switch

4

All

Multisensor function switch. Using bit 
to control.

Caution

: The value is unsigned byte, 

the range is from 0x00 ~ 0xFF.

0

  

Bit0

: Disable magnetic integrate 

illumination to turn ON the lighting 
nodes in the association group 2. 
(1:Disable, 0:Enable)

0

  

Bit1

: Disable PIR integrate 

Illumination to turn ON the lighting 
nodes in the association group 2. 
(1:Disable, 0:Enable)

1

  

Bit2

: Disable magnetic integrate PIR  

to turn ON the lighting nodes in the 
association group 2.  (1:Disable, 
0:Enable) (Default is Disable)

0

  

Bit3

: When Bit2 is 0 (Enable), Are the 

device and the lighting in the same 
room?
  0: In the same room(Default),
  1: In the different room.

Notice

: If this bit is 1, it is 

recommended also set the Bit1 to 1, 
cause    the PIR triggered, doesn't 
mean the people in that room.

0

  

Bit4

: Disable delay 5 seconds to turn 

off the light, when door/window 
closed.  (1:Disable, 0:Enable)

0

  

Bit5

: Disable auto turn off the light, 

after door/window opened to turn on 
the light.  (1:Disable, 0:Enable)

NO.

Name

Def.

Valid

A B C

Description

Notice:

 If bit2 is zero, this setting is 

useless.

Notice:

 If the configuration No.9 is 

zero, this setting is useless.

0

  

Bit6

: Reserve.

0

  

Bit7

: Reserve.

7

(*)

Customer

Function

4

All

Customer function switch, using bit 
control.

Caution

: The value is unsigned byte, 

the range is from 0x00 ~ 0xFF.

0

  

Bit0

: Reserve.

0

  

Bit1

: Enable sending motion OFF 

report.  (0:Disable, 1:Enable)

Note

: Depends on the Bit4,

0: Report Notification CC, 
Type: 0x07, Event: 0xFE
1: Sensor Binary Report, 
Type: 0x0C, Value: 0x00

1

  

Bit2

: Enable PIR super sensitivity 

mode. (0:Disable, 1:Enable)

0

  

Bit3

: Disable send out BASIC OFF 

after door closed. (1:Disable, 
0:Enable)

0

  

Bit4

: Notification Type,  

        0: Using Notification Report. 
        1: Using Sensor Binary Report.

0

  

Bit5

: Disable Multi CC in auto report. 

(1:Disable, 0:Enable)

10

Содержание PST02-A

Страница 1: ...TM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external i...

Страница 2: ...send the Basic Set command to this group And each group support 8 nodes maximum Failed or success in add remove the node ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM dev...

Страница 3: ...led to disable this function by setting the configuration NO 21 to 0 In the default when the temperature is changed to plus or minus one degree Fahrenheit 0 56 degree Celsius the device will report te...

Страница 4: ...ion Power Up Procedure Battery Power Check When the device power up the device will detect the power level of the battery immediately If the power level is too low the LED will continue flash about 5...

Страница 5: ...unction when installation Normal Mode for the normal operation When the event triggered normally the LED won t indicated unless the battery is in the low level the LED will flash once But in the Test...

Страница 6: ...6...

Страница 7: ...elease the cover 2 Hold the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push th...

Страница 8: ...nafter referred to as A tape and another is thinner hereinafter referred to as B tape you can use A tape for the test at the beginning The right way for A tape installation is stick it to the position...

Страница 9: ...tected function And never turn on the light 1 means darkest 99 means brightest 100 means turn off illumination detected function And always turn on the light Notice In none test mode only the value in...

Страница 10: ...people in that room 0 Bit4 Disable delay 5 seconds to turn off the light when door window closed 1 Disable 0 Enable 0 Bit5 Disable auto turn off the light after door window opened to turn on the light...

Страница 11: ...he interval time for auto report the door window state 0 means turn off auto report NO Name Def Valid A B C Description Time door window state The default value is 12 The tick time can setting by the...

Страница 12: ...NSOR_MULTILEVEL_V5 COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD COMMAND_CLASS_SECURITY COMMAND_CLASS_...

Страница 13: ...ures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver i...

Отзывы: