Z-Wave PST02-A Скачать руководство пользователя страница 3

Notification Type: Home Security (0x07)

Event: Motion Detection, Unknown Location (0x08)
Sensor Binary Report (V2)
Sensor Type: Motion (0x0C)

Sensor Value: 0xFF

* Door/Window Report:

When the door/window state changed, the device will unsolicited to

send the report to the nodes in the group 1.

Notification Report (V4)
Notification Type: Access Control (0x06)

Event: Door/Window is open (0x16)

          Door/Window is closed (0x17)
Sensor Binary Report (V2)
Sensor Type: Door/Window (0x0A)

Sensor Value: 0x00 is closed, 0xFF is opened.

* Tamper Report:

Both the 2 tamper keys are pressed over 5 seconds. The device will

into the alarm state. In that state, if any one of the tamper keys be

released, the device will unsolicited to send the report to the nodes in

the group 1.

Notification Report (V4)
Notification Type: Home Security (0x07)

Event: Tampering. Product covering removed (0x03)
Sensor Binary Report (V2)
Sensor Type: Tamper (0x08)

Sensor Value: 0xFF

* Temperature Report:

When the PIR motion detected or the door/window state changed, the

device will unsolicited to send the  “Sensor Multilevel Report” to the

nodes in the group 1.

Sensor Type: Temperature (0x01)

Note: To disable this functionality by setting the configuration N0.5 bit5

to 1.

*** Temperature differential report ***

This function default is enabled, to disable this function by setting the

configuration NO.21 to 0.

In the default, when the temperature is changed to plus or minus one

degree   Fahrenheit   (0.56   degree   Celsius),   the   device   will   report

temperature information to the nodes in the group 1. 

The device will measure the temperature in every one minute. And if

the temperature is over 140 degree Fahrenheit (60 degree Celsius), the

device will always report in each measurement. 

Caution 1

:

 Enable this functionality, it will cause the PIR Motion to 

disable detection when the temperature measurement. In other words,

The PIR motion will blind one second in every one minute.

* Illumination Report:

When the PIR motion detected or the door/window state changed, the

device will unsolicited to send the  “Sensor Multilevel Report” to the

nodes in the group 1.

Sensor Type: Luminance (0x03)

Note:   To  disable  this   functionality   by  setting   the  configuration   N0.5

bit4 to 1.

*** Illumination differential report ***

This function default is disabled, to enable this function by setting the

configuration NO.22 not to zero.

Enable  this  functionality,  the device  will  measure  the  illumination  in

every one minute. And if the illumination is changed to plus or minus

the value (setting by the configuration NO.22), the device will report

illumination information to the nodes in the group 1. 

Caution 1

Enable this function will reduce the battery life about 15% 

~ 20%. And another issue is setting the differential value too small, it 

3

Содержание PST02-A

Страница 1: ...TM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external i...

Страница 2: ...send the Basic Set command to this group And each group support 8 nodes maximum Failed or success in add remove the node ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM dev...

Страница 3: ...led to disable this function by setting the configuration NO 21 to 0 In the default when the temperature is changed to plus or minus one degree Fahrenheit 0 56 degree Celsius the device will report te...

Страница 4: ...ion Power Up Procedure Battery Power Check When the device power up the device will detect the power level of the battery immediately If the power level is too low the LED will continue flash about 5...

Страница 5: ...unction when installation Normal Mode for the normal operation When the event triggered normally the LED won t indicated unless the battery is in the low level the LED will flash once But in the Test...

Страница 6: ...6...

Страница 7: ...elease the cover 2 Hold the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push th...

Страница 8: ...nafter referred to as A tape and another is thinner hereinafter referred to as B tape you can use A tape for the test at the beginning The right way for A tape installation is stick it to the position...

Страница 9: ...tected function And never turn on the light 1 means darkest 99 means brightest 100 means turn off illumination detected function And always turn on the light Notice In none test mode only the value in...

Страница 10: ...people in that room 0 Bit4 Disable delay 5 seconds to turn off the light when door window closed 1 Disable 0 Enable 0 Bit5 Disable auto turn off the light after door window opened to turn on the light...

Страница 11: ...he interval time for auto report the door window state 0 means turn off auto report NO Name Def Valid A B C Description Time door window state The default value is 12 The tick time can setting by the...

Страница 12: ...NSOR_MULTILEVEL_V5 COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD COMMAND_CLASS_SECURITY COMMAND_CLASS_...

Страница 13: ...ures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver i...

Отзывы: