background image

 

Version 0.1 

8 June 2011 

www.2myhome.eu 

 

3.

 

External Screen page 

Description: 

Obtain/Change the current page displayed on external displays using 

the Screen Meta Data Command Class. 

 

What is displayed on each of these pages can be configured using the 

2MyHome Graphical Web interface. 

Size: 

1 byte 

Writable: 

Yes 

Default value:   

 

Possible values:  

 

0 - 255 (depending on configuration) 

 

class: 0x8C COMMAND_CLASS_GEOGRAPHICAL_LOCATION 

The Geographic Location Command Class can be used to set or request the world wide position of the device. 

 

class: 0x9A COMMAND_CLASS_IP_CONFIGURATION 

The IP Configuration Command Class can be used to change the network connection settings of the device. 

Note that the myGate does not perform any domain name lookups, therefore the DNS settings are ignored. 

 

class: 0x72 COMMAND_CLASS_MANUFACTURER_SPECIFIC 

This will report information about the manufacturer. This product will contain the manufacturer ID of 

BeNeXt

Manufacturer ID of 

BeNeXt

 is 138, the ID of this product is 1. 

class: 0x8F COMMAND_CLASS_MULTI_CMD 

The Multi Command Class can be used for sending multiple commands at the same time, increasing Z-Wave 
network performance. 

 

class: 0x92 COMMAND_CLASS_SCREEN_MD 

The Screen Meta Data command class is used to display the status of the various devices in the network, using 

a screen on another Z-Wave device in the network (BeNeXt myDisplay for instance). 

 

class: 0x73 COMMAND_CLASS_POWERLEVEL 

The Powerlevel Command Class is used to check the connection quality between two Z–Wave devices. 

 

class: 0x8A COMMAND_CLASS_TIME 

The Time Command Class can be used by other device to request the current date and time of the day. Note 

that the myGate needs an internet connection to configure its internal clock. 

 

class: 0x86 COMMAND_CLASS_VERSION

 

The Version Command Class can be used to request the Z-Wave and software version of the device.  

 

Содержание myGate

Страница 1: ...tuses of the device as follows A Booting and checking firmware When power is applied the green and orange leds will blink while checking valid firmware After a few seconds the myGate is booted the ind...

Страница 2: ...aken 1 Make sure that the myGate has no devices included if it has please exclude them first using the 2MyHome Graphical Web interface 2 Set the Primary Controller or an Inclusion Controller of the ex...

Страница 3: ...fter which the myGate should be in the same state 1 Press and hold the Learn button the indicator light will switch off 2 Once the indicator light starts blinking orange release the button The indicat...

Страница 4: ...perating temperature 10 C to 50 C Operating humidity 30 to 80 Detailed information myGate myGate is the central part of the home system It will be connected through a router directly to Internet The m...

Страница 5: ...needs to include every product to the network 2myHome will step by step instruct how to do this And finally the configuration which was already made during the play try period will be send to the myGa...

Страница 6: ...uent nodes in the network Being primary is just a role Any controller can be primary but only one controller can be primary at a time The primary controller manages the allocation of node IDs and gath...

Страница 7: ...k class 0x70 COMMAND_CLASS_CONFIGURATION The Configuration Command Class is used to configure or read out the current operation state of the myGate 1 Current Lifestyle Description Obtain Change the cu...

Страница 8: ...is will report information about the manufacturer This product will contain the manufacturer ID of BeNeXt Manufacturer ID of BeNeXt is 138 the ID of this product is 1 class 0x8F COMMAND_CLASS_MULTI_CM...

Страница 9: ...ss 0x26 COMMAND_CLASS_SWITCH_MULTILEVEL class 0x63 COMMAND_CLASS_USER_CODE class 0x86 COMMAND_CLASS_VERSION class 0x84 COMMAND_CLASS_WAKE_UP class 0x71 COMMAND_CLASS_ALARM The Alarm Command Class is u...

Страница 10: ...COMMAND_CLASS_POWERLEVEL The Powerlevel Command Class is used to check the connection quality between two Z Wave devices class 0x75 COMMAND_CLASS_PROTECTION The Protection Command Class can be used t...

Страница 11: ...Class can be used to obtain the version the firmware of a device class 0x84 COMMAND_CLASS_WAKE_UP The Wake Up Command Class is used to configure devices that can sleep turn of power and RF The myGate...

Отзывы: