background image

 

Version 0.1 

8 June 2011 

www.2myhome.eu 

class: 0x72 COMMAND_CLASS_MANUFACTURER_SPECIFIC  

The Manufacturer Specific Command Class is used to identify the manufacturer and device type of a device. 

This information is used to identify and configure the device in the 2MyHome Graphical Web-interface.

 

class: 0x32 COMMAND_CLASS_METER  

The Meter Command Class is used to request the value of a Z-Wave enabled electric, gas, water or other kind 

of meter.

 

class: 0x8F COMMAND_CLASS_MULTI_CMD  

The Multi Command Class can be used for sending multiple commands at the same time, increasing Z-Wave 

network performance. 

class: 0x8E COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION  

The Association Command Class is used to configure devices to send notifications to the myGate. This 

Command Class can be used for devices that consist of multiple sub-devices. See also the Multi Channel 

Command Class.

 

class: 0x60 COMMAND_CLASS_MULTI_CHANNEL  

The Multi Channel Command Class is used to support devices that consist of multiple sub-devices, for instance 

a quad-socket power switch. 

class: 0x73 COMMAND_CLASS_POWERLEVEL  

The Powerlevel Command Class is used to check the connection quality between two Z–Wave devices. 

class: 0x75 COMMAND_CLASS_PROTECTION  

The Protection Command Class can be used to set a device in ‘protected mode’. Protected mode can be seen 

as some kind of child-lock, disabling for example any buttons on the device. 

class: 0x93 COMMAND_CLASS_SCREEN_ATTRIBUTES 

The Screen Attributes Command Class is used to request information about a screens on other devices. This 

information is used for correctly updating these screens using the Screen Meta Data Command Class. 

class: 0x30 COMMAND_CLASS_SENSOR_BINARY  

The Sensor Binary Command Class is used to obtain the state of sensors that support only two states. An 

example can be a door sensor (Open/Closed).

 

class: 0x31 COMMAND_CLASS_SENSOR_MULTILEVEL  

The Multilevel Sensor Command Class is used to obtain the state of a numerical sensor, for example a 

temperature sensor.

 

class: 0x27 COMMAND_CLASS_SWITCH_ALL  

The All Switch Command Class can be used to turn of multiple devices (even different types of devices) at 

exactly the same time.

 

class: 0x25 COMMAND_CLASS_SWITCH_BINARY  

The Binary Switch Command Class can be used to control devices that can be turned on or off (for example a 

power switch).

 

Содержание myGate

Страница 1: ...tuses of the device as follows A Booting and checking firmware When power is applied the green and orange leds will blink while checking valid firmware After a few seconds the myGate is booted the ind...

Страница 2: ...aken 1 Make sure that the myGate has no devices included if it has please exclude them first using the 2MyHome Graphical Web interface 2 Set the Primary Controller or an Inclusion Controller of the ex...

Страница 3: ...fter which the myGate should be in the same state 1 Press and hold the Learn button the indicator light will switch off 2 Once the indicator light starts blinking orange release the button The indicat...

Страница 4: ...perating temperature 10 C to 50 C Operating humidity 30 to 80 Detailed information myGate myGate is the central part of the home system It will be connected through a router directly to Internet The m...

Страница 5: ...needs to include every product to the network 2myHome will step by step instruct how to do this And finally the configuration which was already made during the play try period will be send to the myGa...

Страница 6: ...uent nodes in the network Being primary is just a role Any controller can be primary but only one controller can be primary at a time The primary controller manages the allocation of node IDs and gath...

Страница 7: ...k class 0x70 COMMAND_CLASS_CONFIGURATION The Configuration Command Class is used to configure or read out the current operation state of the myGate 1 Current Lifestyle Description Obtain Change the cu...

Страница 8: ...is will report information about the manufacturer This product will contain the manufacturer ID of BeNeXt Manufacturer ID of BeNeXt is 138 the ID of this product is 1 class 0x8F COMMAND_CLASS_MULTI_CM...

Страница 9: ...ss 0x26 COMMAND_CLASS_SWITCH_MULTILEVEL class 0x63 COMMAND_CLASS_USER_CODE class 0x86 COMMAND_CLASS_VERSION class 0x84 COMMAND_CLASS_WAKE_UP class 0x71 COMMAND_CLASS_ALARM The Alarm Command Class is u...

Страница 10: ...COMMAND_CLASS_POWERLEVEL The Powerlevel Command Class is used to check the connection quality between two Z Wave devices class 0x75 COMMAND_CLASS_PROTECTION The Protection Command Class can be used t...

Страница 11: ...Class can be used to obtain the version the firmware of a device class 0x84 COMMAND_CLASS_WAKE_UP The Wake Up Command Class is used to configure devices that can sleep turn of power and RF The myGate...

Отзывы: