Once the PA-100 has been added to your network, you may assign it to a Group or Scene,
change its status when the All ON or OFF command is received from the controller. It can
also be set in Association with another Z-Wave device to perform a specific duty. Please refer
to the instructions manual of your gateway or remote controller for detail procedures on how
these functions can be set.
About the push button:
There is a single button on PA-100 for manual operation that:
A) Manually turns the connected appliance ON/OFF by pressing the button. It
functions as a toggle switch; if the appliance is ON, pressing the button turns the
appliance OFF and vice versa.
B) Adds (Includes) or Deletes (Excludes) your PA-100 to/from your Z-Wave
network. Please refer to the instructions manual of your gateway or remote controller
for detail procedures on how these actions can be done.
This push button is also backlit with an LED indicator that will be ON whenever the
connected appliance is Off, and turns OFF when the connected device is ON. By changing
the following configuration with your primary controller (if supported), the default status of
the LED indicator can be changed as follows:
Parameter 3
Length: 1 Byte
Valid Values: 0, 1 or 2 (default = 0)
When value = 1, the LED indicator will be ON when the connected appliance is ON, and the
LED indicator will be OFF when the connected appliance is OFF
When value = 2, the LED indicator is always OFF regardless of the load condition
About the Z-Wave 500 Series module with Z-Wave Plus features:
You can use a Z-Wave certified portable or static controller to communicate with the module.
Depending on the capability of your controller or gateway software, the following simple to
advanced operations can be performed. Please refer to the controller or gateway's manual for
details.
1. Turn the appliance On/Off
2. Add(Include) or Delete(Exclude) your PA-100 to/from your network
3. Assign your PA-100 to a specific Group/Scene and/or to include your PA-100 as part
of your All ON or OFF command
4. Over-the-Air firmware update by your gateway or static controller
5. Lifeline function which automatically notifies the associated modules and the network
that a manually reset device is no longer in the network, thus, the corresponding
association becomes invalid
Please note that the module will be OFF after a power failure
SPECIFICATIONS
Model: PA-100
Input power: 120 VAC, 60 Hz.
Max output loading: 900W incandescent, 200W CFL/LED, ½ horsepower motor and 15A,
1800W resistive load.
Radio frequency: 908.4 MHz/916 MHz.
Wireless range: up to 130 ft line of sight between the controller
and the other available nodes.
Normal operating temperature: 77°F (25°C)
For indoor use only.