background image

2.8 Label and compliance information

Host product manufacturers need to provide a physical or e-label stating “Contains FCC ID

2.10 Additional testing, Part 15 Subpart B disclaimer

The modular transmitter is

only

FCC authorized for FCC Part 15 Subpart C 15.247 & 15.207 & 15.209

and that the host product manufacturer is responsible for compliance to any other FCC rules that apply

to the host not covered by the modular transmitter grant of certification. If the grantee markets their

product as being Part 15 Subpart B compliant (when it also contains unintentional-radiator digital

circuity), then the grantee shall provide a notice stating that the final host product still requires Part 15

Subpart B compliance testing with the modular transmitter installed

2

A

LI

B-

ZMEMP

C

IEZWZ

B

With their finished product.

 

2.9 Information on test modes and additional testing requirements

IEEE

 8

02.15.1

(Z

igbee

/T

hre

a

d

):

Operation Frequency:2402~2480MHz

Number of Channel:40 Channels

Modulation Type:O

Q

PSK

Antenna Type:External antennai (Provided by LAB)

Antenna Gain(Peak):1.5 dBi (Provided by LAB)

Z-Wave

Operation Frequency:908.42MHz,912MHz,916MHz,921MHz

Number of Channel:4 Channels

Modulation Type:GFSK

Antenna Type:External antennai (Provided by LAB)

Antenna Gain(Peak):1.5 dBi (Provided by LAB)

Host manufacturer must perfom test of radiated & conducted emission and spurious emission, etc

according to the actual test modes for a stand-alone modular transmitter in a host, as well as for

multiple simultaneously transmitting modules or other transmitters in a host product.

Only when all the test results of test modes comply with FCC requirements, then the end product can

 

be sold legally.

.

Z-Wave & Zigbee/Thread mPCIe Adaptor

7

Содержание ZME mPCIe ZW ZB

Страница 1: ...CIe adaptor in your embedded hardware 2 Install Z Way software The maximum potential of the Z Wave Zigbee Thread mPCIe adaptor is achieved together with Z Way software To install Z Way on your embedde...

Страница 2: ...t can be found on the website https z wave me products mpcie You can change the radio frequency of the Z Wave Zigbee Thread mPCIe Adaptor at any time by going to the Expert UI http IP 8083 expert Netw...

Страница 3: ...emperature sensor In this case there will be three separate widgets 7 with individual settings 8 Advanced automation can be configured using local and online Apps Apps allow you to set up rules like I...

Страница 4: ...ine of sight Dimensions 30 x 51 x 4 mm Interface USB mPCIe form factor USB driver Silicon Labs CP2105 Z Wave frequency range 865 869 MHz Europe EU India IN Russia RU China CN South Africa EU Middle Ea...

Страница 5: ...chnician for help FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated...

Страница 6: ...cluding the transmitter and obtaining a separate FCC authorization As long as the conditions above are met further transmitter test will not be required However the host manufacturer is still responsi...

Страница 7: ...talled 2ALIB ZMEMPCIEZWZB With their finished product 2 9 Information on test modes and additional testing requirements IEEE 802 15 14 Zigbee Thread Operation Frequency 2402 2480MHz Number of Channel...

Отзывы: