.5 Trace antenna designs

Not applicable. The module has its own antenna, and doesn’t need a host’s printed board microstrip

trace antenna etc.

2.6 RF exposure considerations

The module must be installed in the host equipment such that at least 20mm is maintained between

theantenna and users’ body; and if RF exposure statement or module layout is changed, then the host

product manufacturer required to take responsibility of the module through a change in FCC ID or new

application. The FCC ID of the module cannot be used on the final product. In these circumstances,

the host manufacturer will be responsible for re-evaluating the end product (including the transmitter)

and obtaining a separate FCC authorization.

As long as the conditions above are met, further transmitter test will not be required. However, the
host manufacturer is still responsible for testing their end-product for any additional compliance
requirements required with this module installed (for example, digital device emissions, PC peripheral
requirements, etc.)

2.7 Antennas

Antenna Specification are as follows:

Antenna Type:External antennai
Antenna Gain(Peak):1.5 dBi (Provided by LAB)
This device is intended only for host manufacturers under the following conditions:
The transmitter module may not be co-located with any other transmitter or antenna;
The module shall be only used with the External antenna(s) that has been originally tested and
certified with this module. The antenna must be either permanently attached or employ a ‘unique’
antenna coupler.

.

6

Содержание ZME mPCIe ZW ZB

Страница 1: ...CIe adaptor in your embedded hardware 2 Install Z Way software The maximum potential of the Z Wave Zigbee Thread mPCIe adaptor is achieved together with Z Way software To install Z Way on your embedde...

Страница 2: ...t can be found on the website https z wave me products mpcie You can change the radio frequency of the Z Wave Zigbee Thread mPCIe Adaptor at any time by going to the Expert UI http IP 8083 expert Netw...

Страница 3: ...emperature sensor In this case there will be three separate widgets 7 with individual settings 8 Advanced automation can be configured using local and online Apps Apps allow you to set up rules like I...

Страница 4: ...ine of sight Dimensions 30 x 51 x 4 mm Interface USB mPCIe form factor USB driver Silicon Labs CP2105 Z Wave frequency range 865 869 MHz Europe EU India IN Russia RU China CN South Africa EU Middle Ea...

Страница 5: ...chnician for help FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated...

Страница 6: ...cluding the transmitter and obtaining a separate FCC authorization As long as the conditions above are met further transmitter test will not be required However the host manufacturer is still responsi...

Страница 7: ...talled 2ALIB ZMEMPCIEZWZB With their finished product 2 9 Information on test modes and additional testing requirements IEEE 802 15 14 Zigbee Thread Operation Frequency 2402 2480MHz Number of Channel...