Product
ZX
Date:
2018.09.19
Page:
31 of 62
Z-Laser Optoelektronik GmbH
Merzhauser Str. 134
D-79100 Freiburg
Tel.: (0761)29644-44
Fax: (0761)29644-55/56
Operation manual
Document-ID: UI-ZL-140011-0.9-2018-09-19
0.9
Author:
CSCH
Merzhauser Str. 134 ~ 79100 Freiburg ~ Tel.: +49-(0)761-29644-44 ~ Fax: +49-(0)761-29644-55
www.z-laser.com
GET_PART_NO
– reads the part number of the LDU by 9 ASCII bytes (0x30…0x39).
no
protection
GET_POWER_OUT_ABS
– reads the absolute optical output power of the LDU in
0.01mW steps as unsigned.
no
protection
GET_MANUFACTURER_ID
– reads the Manufacturer ID of the LDU by 9 ASCII bytes
(0x30…0x39).
no
protection
GET_PERCENTAGE_POWER_LIMIT
– reads the user defined percent power limits
no
protection
GET_POWER_OUT_ABS
– reads the absolute optical output power of the LDU in
0.01mW steps as unsigned.
no
protection
GET_FW_VERSION
- reads the firmware version as unsigned integer value (3 bytes)
no
protection
WR-Device-ID CMD (0xA4)
RD-Device-ID System Status
ASCII Digit 9
(Status followed by CRC and trailing fill bytes when data can not be returned instantaneously)
Hi-Byte CRC
Lo-Byte CRC
Hi-Byte CRC
Lo-Byte CRC
ASCII Digit 0
…
Digi
0x01
WR-Device-ID CMD (0xA6)
RD-Device-ID System Status
Power Value Hi
(Status followed by CRC and trailing fill bytes when data can not be returned instantaneously)
Hi-Byte CRC
Lo-Byte CRC
Hi-Byte CRC
Lo-Byte CRC
Power Val Lo
WR-Device-ID CMD (0xBA)
RD-Device-ID System Status
ASCII Digit 9
(Status followed by CRC and trailing fill bytes when data can not be returned instantaneously)
Hi-Byte CRC
Lo-Byte CRC
Hi-Byte CRC
Lo-Byte CRC
ASCII Digit 0
…
Digi
WR-Device-ID CMD (0xC4)
RD-Device-ID System Status
Max Perc Limit
(Status followed by CRC and trailing fill bytes when data can not be returned instantaneously)
Hi-Byte CRC
Lo-Byte CRC
Hi-Byte CRC
Lo-Byte CRC
Min Perc Limit
WR-Device-ID CMD (0xA6)
RD-Device-ID System Status
Power Value Hi
(Status followed by CRC and trailing fill bytes when data can not be returned instantaneously)
Hi-Byte CRC
Lo-Byte CRC
Hi-Byte CRC
Lo-Byte CRC
Power Val Lo
WR-Device-ID CMD (0xF0)
RD-Device-ID System Status
Major Version Minor Version Build
(Status followed by CRC and trailing fill bytes when data can not be returned instantaneously)
Hi-Byte CRC
Lo-Byte CRC
Hi-Byte CRC
Lo-Byte CRC