DISTRIBUTION ZHC 

 

User Manual and Installation Guide

 

 

Operating Environment 

Operating Temperatures 

0°C to 55°C 

Relative Humidity 

5% to 95% (non-condensing) 

Storage Temperature 

-40°C to 70°C 

LED Indication Lights 

Front Panel LEDs 

Rear Panel LEDs 

RED LED: ON when unit is in MASTER mode 

RED LED: SLAVE MODE with LOCKED CASCADE 
Distance 

AMBER LED: ON when unit is in SLAVE mode 

AMBER LED: MASTER MODE transmitting TONE 

GREEN LED: Flashing GREEN - power supply error 

GREEN LED: Blinking indicates distance LOCK timer is 
running 

GREEN LED: Solid GREEN - power supply normal 

 

ALL LEDs ON: UNIT IS IN NATIVE MODE 

 

Conformance 

 

FCC Part 15 Subpart B Compliance 

 

UL/CSA Listed 

 

Resolution 

Video Resolution :    Z-Band system performs no manipulation of the video programming.    All visible and 
non-visible content is passed through to the viewing/decoding equipment.    This includes but is not limited 
to closed captioning, EAS data, alternate languages, and any resolutions within the video channel. 

 

 

 

 

 

 

 

 

 

 

Содержание ZBT0100050

Страница 1: ...anual RF DISTRIBUTION HUB FOR BUT NOT LIMITED TO P N S ZBT0100052 24 PORT HUB ZBT0100055 24 PORT HUB W FIBER RX ZBT0100051 16 PORT HUB ZBT0100054 16 PORT HUB W FIBER RX ZBT0100050 8 PORT HUB ZBT010005...

Страница 2: ...ackage Contents 4 Product Description 4 Specifications 5 Proper cable Layout design Fiber Loss Budget 7 Required Equipment for Installation 7 Hardware Installation and Master Unit Set Up Coax Backbone...

Страница 3: ...ice This device is supplied with the appropriately rated power supply The use of any other power supply could cause damage and invalidate the manufacturer s warranty DO NOT connect the power cord to t...

Страница 4: ...4 end devices Active baluns Z Band P N ZBT00100085 Recommended for full feature set P N ZBT0010021 Reduced feature set which go to a TV Tuner The hub accepts either a 75 RF input or an optional Fiber...

Страница 5: ...7 8 on front panel CATEGORY cables IP Outbound IP Output 10 100 max on pins 1 2 3 6 with SWITCH option RS 232 Compatible in future RF System Requirements Frequencies Frequency of operation 57 861 MHz...

Страница 6: ...MASTER MODE transmitting TONE GREEN LED Flashing GREEN power supply error GREEN LED Blinking indicates distance LOCK timer is running GREEN LED Solid GREEN power supply normal ALL LEDs ON UNIT IS IN N...

Страница 7: ...especially important for the coax cascade as it can be done with different designs some which might not be optimum IT IS RECOMMENDED THAT YOU USE THE FREE Z BAND DESIGN SERVICE Z BAND WILL PROVIDE A D...

Страница 8: ...0085 or ZBT0010021 with patch cords at each video drop using the TO WALL RJ on the balun Using good quality RG6 Cable with F connectors attach to Balun and to TV Tuner 4 At RF headend adjust signal so...

Страница 9: ...another purposes such as a coax master or a slave unit please contact Z Band for assistance in reconfiguring the unit All connections in the fiber links must be either fusion spliced or Angle Polished...

Страница 10: ...ter problems If your feed is bad please contact your Cable Service Provider to correct These measurements should be taken at the end of the cable that is to attach to the Master ZHC 4 Connect the fibe...

Страница 11: ...een units can be up to 400 when using RG6 cable and 600 when using RG11 cable 5 Always try and design to keep the lowest level Cascade Example Closet has the MASTER and 3 SLAVE units The proper way to...

Страница 12: ...20 mins This is indicated by a flashing Green LED on the rear of the enclosure 6 When the unit has detected a steady tone for 20 minutes the unit will lock as indicated by a solid RED LED on the rear...

Страница 13: ...ttings 7 Repeat this procedure for the next higher slave level if necessary 8 If the next highest Slave level in in a different closet make sure to bring up the closet with the lower Slave level fist...

Отзывы: