Meter Level – Verometer
This display illustrates the Verometer level in per-
cent. As odorant is pumped out of the Verometer,
the N-300 controller will automatically refill the meter
when the meter level reaches 0%, figure 122.
To manually fill the Verometer, figure 122a, press the *Fill
key and follow the instructions. The following represent There
conditions that will result in a meter alarm indication.
Meter Alarms – Verometer
These are of the displays containing 12 alarm and non-alarm indicators,
figures 123-134, to provide information on Verometer operation.
• Vmtr-Cable, the Verometer cable is not communicat-
ing to the controller, figure 123.
• No Fill, the meter has failed to fill, figure 124.
a. The meter has failed to fill to 100% within six minutes
b. The fill was inhibited due to leakage detection
• Slow Fill, the meter has failed to fill within three minutes,
figure 125.
• Fill Valve, the fill valve has failed to close, figure 126.
• OdorInlet-Cable, inlet fill valve pressure transmitter is
not communicating with the controller, figure 127.
• OdorInlet Lo, the required inlet pressure of odorant is
lower than allowed, figure 128.
• OdorInlet Hi, the required inlet pressure of odorant is
higher than allowed, figure 129.
• XTank-Cable, the expansion tank cable outlet fill valve
pressure transmitter is not communicating with the controller,
figure 130.
• XTank Low, the expansion tank pressure has fallen
below the programmed low-pressure setting, figure 131.
• XTank Hi, the expansion tank pressure has risen above
the programmed high-pressure setting, figure 132.
Meter Indicators, non-alarm
• Over Fill, the meter has been filled in excess of 112%.
a. The Verometer Fill Rate is too fast, in excess of
10 seconds, figure 133.
b. The verometer Fill Valve has failed to close.
• Fill Rate, the meter has filled too fast, in excess of
10 seconds, figure 134.
Figure 122
Figure 123
pmp bat vmtr sig tnk
Meter Level 100.0%
*Fill
pmp bat vmtr sig tnk
Meter Level 00.0%
*Fill
pmp bat vmtr sig tnk
Fill Verometer?
*No *Yes
pmp bat VMTR sig tnk
Meter Level 0.0%
*Fill
Umtr-Cable
pmp bat VMTR sig tnk
Meter Level 0.0%
*Fill
No Fill
pmp bat VMTR sig tnk
Meter Level 0.0%
*Fill
Slow Fill
pmp bat VMTR sig tnk
Meter Level 106.1%
*Fill
Flvalve-Fail
pmp bat VMTR sig tnk
Meter Level 99.6%
*Fill
OdorInlet-Cabl
pmp bat VMTR sig tnk
Meter Level 99.6%
*Fill
Odor Inlet-Low
pmp bat VMTR sig tnk
Meter Level 99.6%
*Fill
Odor Inlet-Hi
pmp bat VMTR sig tnk
Meter Level 99.6%
*Fill
XTank-Cable
pmp bat VMTR sig tnk
Meter Level 99.6%
*Fill
XTank-Low
pmp bat VMTR sig tnk
Meter Level 99.6%
*Fill
XTank-High
pmp bat VMTR sig tnk
Meter Level 104.3%
*Fill
Over-fill
pmp bat VMTR sig tnk
Meter Level 104.3%
*Fill
Fillrate
Figure 122a
Figure 130
Figure 133
Figure 124
Figure 125
Figure 126
Figure 127
Figure 128
Figure 129
Figure 131
Figure 132
Figure 134
Содержание NJEX 7300L
Страница 1: ...NJEX 7300L L P G O D O R I Z A T I O N S Y S T E M...
Страница 2: ......
Страница 3: ...THE NJEX 7300L INSTRUCTION OPERATING MANUAL Version NJEX7300L 10012003...
Страница 4: ......