Operation Specifications
Maximum Output:
5,760 cc/day
(5.76 liters/day)
Maximum Operating Pressure: 1,500 psig
(124 Bar (g))
Pump Displacement: .2 - .4 cc/Stroke
Operating Temp Range: 0 to 140 degrees F.
(17˚C to 60˚C)
Power Supply:
Internal Battery Pack
Flow Signal:
Dry Contact or
Voltage
Pulse
Theory of Operation
The DynaPak 2010 Sampler is a pipeline
mounted system which uses the pneumatically
operated, positive displacement DynaPak 2000
pump, the Z-65 timer/controller, the YZ filter/reg
-
ulator and a low power solenoid valve to obtain
gas samples.
The 2010 provides two modes
of operation:
A. Time-based sampling:
In this mode of operation, the 2010 extracts a
gas sample from the pipeline at regular time in-
tervals. The volume of the sample is set by the
operator using the volume adjustment feature of
the DP-2000 pump. The Z-65 controller oper-
ates as a recycling timer, periodically energizing
a low power solenoid valve. Energizing the so-
lenoid valve allows actuation gas to stroke the
DP-2000 pump. The rate at which this occurs
is a function of operator input. Two 10 position
switches are used to set the off time interval.
The number of times the solenoid output is ac-
tivated is recorded by the onboard LCD stroke
indicator.
B. Proportional-to-Flow sampling:
In this mode of operation, the Z-65 counter
operates as a dividing counter. The Z-65 coun-
ter periodically energizes a low power solenoid
valve. As in the time-based mode of operation,
this allows actuation gas to stroke the DP-2000
pump. The rate at which this occurs is a function
of operator input as well as the host computer
or other device that inputs pulses per volume
metered. The two 10-position switches on the
Z-65 are used to set the number of pulses the
counter will count before activating the solenoid
output. The number of times the solenoid output
is activated is recorded by the onboard LCD
stroke indicator. Sample volume is again con-
trolled using the DP-2000 volume adjustment
knob.
In both modes of operation, the Z-65 timer/
counter operates using a replaceable internal
battery pack. The battery pack condition is
monitored by way of two indicator LEDs. When
the battery pack needs replacement, the red
LED will illuminate when the solenoid output is
activated. If the battery pack is good, the green
LED will illuminate when the solenoid is acti-
vated.