YZ Systems Milton Roy • 201 Ivyland Road • Ivyland, Pennsylvania • USA • 18974 • P: 281.362.6500 • www.yzsystems.com
DP-2010 ver.05-2018
Page 14
s
eCTion
7: m
eChaniCal
s
ysTem
DP-2000 Sample Pump
dix A, page 25
, is a positive displacement
plunger pump. It’s robust design provides
for dependable sampling service, while also
providing a simple to maintain pump, with
few internal components. The pump has an
adjustable displacement of .1 to .4 cc per
stroke. The set displacement may be viewed
at the volume adjustment knob,
, located on the top of the
DP-2000 pump. Adjustment is simple. Turn
the volume adjustment knob clockwise to
increase the pump volume displacement per
stroke, or turn the volume adjustment knob
counter clockwise to decrease the pump
volume displacement per stroke. Final con-
trol of the volume of sample to be gathered
during the sample cycle period, is achieved
by the controller.
This pump has internal pressure balancing
capabilities that allows the pump to func-
tion properly when the pipeline pressure is
greater than the sample vessel pressure, or
when the sample vessel pressure is greater
than the pipeline pressure.
Each time the pump strokes, product pre-
viously captured in the pump chamber is
forced towards the sample cylinder. As the
pump plunger returns to a resting state a
new fresh sample is captured in the pump.
Once the pump completes its stroke, the
cycle is ready to begin again.
Filter Regulator
The DynaPak Filter Regulator,
, is a stainless steel filtered
regulator to supply the supply gas required
to actuate the sample pump. It is capable of
providing actuation pressure from pipeline
pressures to required actuation pressures in
a single dependable step.
Maintenance is minimal, but is certainly de-
pendant on gas quality. Should the gas sup-
plied to the filter regulator require significant
filtration, replacement of the filter may be
.
Содержание DynaPak DP-2010
Страница 1: ...DynaPak Gas Sampler S Y S T E M S U P P O R T M A N U A L DP 2010 V e r s i o n s D F J K L S T D ...
Страница 2: ...DP 2010 Instruction Operating Manual Version 05 2018 ...
Страница 38: ...201 Ivyland Road Ivyland PA 18974 P 800 653 9435 P 281 362 6500 E sales yzhq com www yzsystems com ...